Publication 1760-UM002B-EN-P - March 2005
Wiring with Pico GFX-70 4-87
The counter has counted 21000 pulses.
Behavior when value range is exceeded
• The function block sets the switching contact CI..CY to status 1.
• The function block retains the value of the last valid operation.
Inputs
The function block inputs >SH, >SL and >SV can have the following operands:
• Constants
• Markers MD, MW, MB
• Analog inputs IA01 to IA04
– IA01: terminal I7
– IA02: terminal I8
– IA03: terminal I11
– IA04: terminal I12
• Analog output QA01
• Actual value
… QV> of another function block
Actual Value ..QV>
The actual value …QV> can be assigned the following operands:
• Markers MD, MW, MB
• Analog output QA01
IMPORTANT
Counter CI counts every rising edge on the counter input.
If the value range is exceeded, the switching contact CI
..CY switches to status 1 for one cycle per rising edge
detected.
IMPORTANT
The actual value is only erased in RUN mode with a
selective reset signal.