Rockwell-automation 2098-DSD-xxx Ultra3000 Host Commands for Serial In Manual do Utilizador Página 103

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 176
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 102
Publication 2098-RM003A-EN-P October 2001
Command Reference 2-87
Position Loop Izone
Velocity Loop P Gain
Format: :aa015fddddcc<cr>
Parameter
Code:
0x015
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddd Units: counts
Minimum
Value:
0x0000
Maximum
Value:
0x7FFF
Default: 0x03F8
Format: :aa01Ffddddcc<cr>
Parameter
Code:
0x01F
Valid Function
Codes:
0x0 = Read Working Value
0x1 = Write Working Value
0x2 = Read Non-Volatile Value
0x3 = Write Non-Volatile and Working Values
0x4 = Copy Non-Volatile Value to Working Value
0x5 = Copy Working Value to Non-Volatile Value
0x6 = Read Default Value
0x7 = Copy Default Value to Non-Volatile and Working Values
0x8 = Read Minimum Value
0x9 = Read Maximum Value
Valid Exception
Codes:
0x03 = EEPROM Write Error
0x04 = Data Below Minimum
0x05 = Data Above Maximum
0x08 = Invalid Function Code
Data Fields: dddd
Minimum
Value:
0
Maximum
Value:
4000
Default: 200
Vista de página 102
1 2 ... 98 99 100 101 102 103 104 105 106 107 108 ... 175 176

Comentários a estes Manuais

Sem comentários