Rockwell-automation 2092-DAx Ultra1500 Host Commands for Serial Commun Manual do Utilizador Página 58

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 70
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 57
Publication 2092-RM001A-EN-P — March 2005
2-46 Command Reference
[Pr – 9.58] Oscilloscope Configuration
[Pr – 9.59] Oscilloscope Scaling
Ultraware Name: Scope Config
Data Size: 21 digits
Value Description
0 to 1 Channel A Signal
See Monitor Variables on page A-3 for a list
of variables.
2 to 3 Channel B Signal
See Monitor Variables on page A-3 for a list
of variables.
4 Channel A Signal
0 = Auto (default)
1 = Manual
5 Channel B Scale Type
0 = Auto (default)
1 = Manual
6 to 7 Sample Period
8 to 9 Samples per Division
10 to 12 Trigger Signal
See Monitor Variables on page A-3 for a list
of variables.
13 Trigger Mode
14 Pretrigger, %/1
15 to 22 Trigger Threshold
Default:
0x00000000000000000000000000000000
Operating Mode: All
Data Size: 32 digits
Value Description
0 to 7 Channel A Scale
8 to 14 Channel A Offset
15 to 23 Channel B Scale
24 to 31 Channel B Offset
Default:
0x00000000000000000000000000000000
Operating Mode: All