Rockwell-automation 2092-DAx Ultra1500 Host Commands for Serial Commun Manual do Utilizador Página 54

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 70
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 53
Publication 2092-RM001A-EN-P — March 2005
2-42 Command Reference
[Pr – 9.16] Electrical Cycle Length
[Pr – 9.17] Encoder Lines / Meter
[Pr – 9.18] Maximum Linear Speed
[Pr – 9.19] Motor Thermal Protection Enable
[Pr – 9.20] Motor Thermostat
Ultraware Name: General: Electrical Cycle
Range: 100 to 10000
Units: Millimeters * 10
Operating Mode: All
Ultraware Name: Feedback: Lines/Meter
Range: 4000 to 10000000
Units: Lines
Operating Mode: All
Ultraware Name: Rating: Maximum Speed
Range: 32 - 2
15
- 1
Units: meters per second * 256
Operating Mode: All
Ultraware Name: Thermal: Software Protection
Range: 0 to 1
Units Description
0 No - Disabled
1 Yes - Enabled
Operating Mode: All
Ultraware Name: Thermal: Integral Thermostat
Range: 0 to 1
Units Description
0 No
1 Yes
Operating Mode: All
Vista de página 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 69 70

Comentários a estes Manuais

Sem comentários