Rockwell-automation MPMA Integrated Multi-Axis Linear Stages Manual do Utilizador Página 118

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 117
118 Rockwell Automation Publication MPMA-UM001B-EN-P - November 2010
Appendix D Home to Torque-level Example
Drive Bipolar Torque Limit
Adjustment
When homing an axis to a mechanical hard-stop, set the Home Torque-level
value above the torque value required to move the system, but low enough not to
cause problems with the system mechanics. As part of the process of homing to a
torque limit, limit the Peak Torque value to a level 10% above the Home Torque
value to reduce the stresses on the mechanics and to eliminate the chance of an
over-current error.
Limit the Peak Torque value before issuing the homing instruction (MAH) and
reset the Peak Torque field to the original value after homing completes.
Table 52 - Bipolar Torque Limit Adjustment
IMPORTANT
The 10% value is an estimated starting point. This value may need
adjustment based on the application requirements.
Vista de página 117
1 2 ... 113 114 115 116 117 118 119 120 121 122 123 ... 135 136

Comentários a estes Manuais

Sem comentários