Rockwell-automation IASIMP Computer Numerical Control (CNC) Machining Manual do Utilizador Página 67

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 278
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 66
Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012 67
FANUC CNC Configuration Chapter 3
6. Press either the + softkey or the right arrow
function key to advance to the chapter
selection for EtherNet/IP scanner settings,
EIP S SET.
7. Press the (OPRT) softkey to display available
operations for the EtherNet/IP scanner
settings.
8. Press either the + softkey or the right arrow
function key to advance to the operation
selection for restore.
9. Press the RESTORE softkey to display
available operations for the EtherNet/IP
scanner restore operations.
10. Press the EXECUTE softkey to copy the
parameters from the external USB device to the
CNC parameter memory.
11. Power down the CNC to accept the changes to
the EtherNet/IP settings.
12. Power up the CNC, then repeat step 2
...step 11
for the Ethernet adaptor settings (at step 6
select EIP A SET).
The Ethernet board is now configured for the
connection to the supervisory PLC that uses
the EtherNet/IP protocol.
Vista de página 66
1 2 ... 62 63 64 65 66 67 68 69 70 71 72 ... 277 278

Comentários a estes Manuais

Sem comentários