Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 31
Chapter 3
General Commands (ASCII)
This chapter defines the general ASCII commands available to control a
Kinetix 3 drive.
Read Parameter (SET)
Attribute Value
Command SET
Description Read parameter value
Format STX ID # SET PPP : BSS ETX
Data Argument Description
PPP Parameter #; for example, [Pr - 2.03]
, PPP=203=0x0CB
Refer to this chapter, Appendix A
, Standard Drive Parameters,
and Appendix B, Indexing Drive Parameters for a available
parameter descriptions.
Response Format STX ID $SET V : BSS ETX
Response Data Argument Description
V Bit-field type = 4-byte hexadecimal value.
Integer type = Signed integer of variable length