Rockwell-automation 2071-Axx Kinetix 3 Component Servo Drive Serial Ho Manual do Utilizador Página 119

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 146
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 118
Rockwell Automation Publication 2071-RM001B-EN-P - April 2013 119
Indexing Drive Parameters Appendix B
[IN01.03] Creep Velocity
Ultraware Name Creep Velocity
Description For the To Sensor, then Back to Marker Homing Type, the
velocity used for all remaining homing motion after the
motor decelerates to a stop when it finds the sensor edge.
Range Value Description
0 …6000 The velocity used for all
homing motion after the
motor decelerates to a stop
at the sensor edge.
Default 20
Units Rotary motors: rpm; Linear motors: mm/s
Access Set
Changeable Status Disable Drive
When Enabled Disable Drive
Applicable Operating Mode Indexing
Modbus Address 5203
[IN01.04] Homing Acceleration/Deceleration
Ultraware Name Homing Acceleration/Deceleration
Description The rate of acceleration and deceleration used during
homing.
Range Value Description
1 …2,147,483,647 The velocity used for all
homing motion after the
motor decelerates to a stop
at the sensor edge.
Default 6250
Units 10
-2
* rev/s
2
for rotary,
mm/s
2
for linear
Access Set
Changeable Status Disable Drive
When Enabled Disable Drive
Applicable Operating Mode Indexing
Modbus Address 5204 …5205
Vista de página 118
1 2 ... 114 115 116 117 118 119 120 121 122 123 124 ... 145 146

Comentários a estes Manuais

Sem comentários