Publication 1203-5.14 – September 1998
3-8 Configuring the 1203-SSS Converter
Editing Parameters in the 1203-SSS
Converter
The 1203-SSS converter has some configurable parameters. Refer to
Appendix B, 1203-SSS Converter Parameters, for a detailed list. If
you do not want to use the converter’s default settings, edit its
parameters.
To edit parameters using a serial connection, you need to:
1. Establish a serial connection to access the converter’s software.
Refer to the “Establishing a Serial Connection with the 1203-SSS
Converter” section earlier in this chapter.
2. Press 1 to select 1> Display Setup Parameters. The first
parameter appears on the bottom of the screen.
Figure 3.8
Example Display Parameters Screen
3. If necessary, scroll through the list of parameters by pressing the
Up Arrow or Down Arrow key.
4. Edit parameters as necessary using the Left Arrow and Right
Arrow keys. Refer to the “Navigation Techniques” section earlier
in this chapter for information on changing values. Refer to
Appendix B, 1203-SSS Converter Parameters, for valid values.
5. Reset power to the converter by setting the Reset Adapter (5)
parameter to Enable and pressing Enter.