106 Rockwell Automation Publication 520COM-UM001B-EN-E - March 2013
Chapter 7 Using Multi-Drive Mode
Drive 4 Control Routine
0
5
(End)
Copy File
Source
Dest
Length
Drive_Input_Image[11]
Drive_4_Feedback
1
COP
12
Copy File
Source
Dest
Length
Drive_4_Reference
Drive_Output_Image[9]
1
COP
15
Return from Subroutine
RET
Drive_Input_Image[10].0 Drive_4_Status_Ready
This section takes the data from the input area and moves it to specic tags (Logic Status bits and Feedback) for use
elsewhere in the ladder program.
This section takes the data from specic tags (Logic Command bits and Reference) and moves them to the output
image area for transmission to the scanner.
Drive 4 parameters are accessed by adding 20480 decimal (5000 hex) to the desired parameter number. For example,
to access parameter P109 an Instance of 20589 (20480 + 109) is used.
1
Drive_Input_Image[10].1 Drive_4_Status_Active
2
Drive_Input_Image[10].3 Drive_4_Status_Forward
3
Drive_Input_Image[10].7 Drive_4_Status_Faulted
4
Drive_Input_Image[10].8 Drive_4_Status_At_Reference
6
Drive_4_Command_Stop Drive_Output_Image[8].0
7
Drive_4_Command_Start Drive_Output_Image[8].1
8
Drive_4_Command_Jog Drive_Output_Image[8].2
9
Drive_4_Command_Clear_Faults Drive_Output_Image[8].3
10
Drive_4_Command_Forward Drive_Output_Image[8].4
13
Perform_Parameter_Read_4
EN
DN
ER
11
Drive_4_Command_Forward Drive_Output_Image[8].5
Message
Message Control Parameter_RD_Message_4
MSG
14
Perform_Parameter_Write_4
EN
DN
ER
Message
Message Control Parameter_WR_Message_4
MSG
Explicit Messaging Example
Drive 4 Control Subroutine