D-4 Use with DriveExecutive Software
PowerFlex 1203-USB Converter User Manual
Publication DRIVES-UM001D-EN-P
9. Enter the following settings.
10. Click OK.
The Configure Drivers dialog box appears.
11. Verify that the status of the newly created driver is ‘Running’.
12. Click Close.
13. From the Communications menu, choose RSWho to display the browse
window.
14. Expand the treeview in the left pane to display the ‘DPI’ or ‘DSI’ icon
to verify that the driver is communicating with the device.
The browse window should look similar to this example window.
Configuration Field Setting
Comm Port Select the same COM port established during installation of the
1203-USB driver (noted in step 1 on page D-2). For this example,
COM5 is used.
Device 1770-KF2/1785-KE/SCANport
Baud Rate 115200
Station Number 00 (default)
Parity None (default)
Error Checking BCC (default)
Stop Bits 1 (default)
Protocol Full Duplex (default)