32 Rockwell Automation Publication 56RF-UM001A-EN-P - October 2011
Chapter 3 Electrical Installation
Transceiver Connection
The M12 QD female connector for the transceivers is shown below. Pin 5 is the
cable shield connection and is connected only at the block to functional earth
(FE).
Digital Input Connection
The female M12 QD input connector is shown below.
Digital Output Connection
The female M12 QD output connector is shown below.
Pin Function
124V DC power
2 Data +
3 24V common
4 Data -
5 Shield/FE
Pin Function
124V DC power
2 Not used
3 24V common
4 Digital input
5 Shield/FE
Pin Function
1 Not used
2 Not used
3 24V common
4 Digital output
5 Shield/FE