Vista de página 0
PowerFlex® 22-COMM-B
BACnet MS/TP Adapter
Firmware Version 1.xxx
User Manual
Vista de página 0
1 2 3 4 5 6 ... 71 72

Resumo do Conteúdo

Página 1 - BACnet MS/TP Adapter

PowerFlex® 22-COMM-BBACnet MS/TP AdapterFirmware Version 1.xxxUser Manual

Página 2 - Important User Information

1-2 Getting Started The adapter features include:• Typical mounting in a PowerFlex 40 or PowerFlex 400 drive. The adapter can also be installed in a

Página 3 - Summary of Changes

Getting Started 1-3 The adapter is compatible with Allen-Bradley PowerFlex 4-Class (Component-Class) drives and other products that support an inter

Página 4

1-4 Getting Started Please read the following safety precautions carefully. Safety Precautions!ATTENTION: Risk of injury or death exists. The Powe

Página 5 - Table of Contents

Getting Started 1-5 !ATTENTION: Risk of injury or equipment damage exists. When a system is configured for the first time, there may be unintended

Página 6

1-6 Getting Started This section is provided to help experienced users quickly start using the adapter. If you are unsure how to complete a step, re

Página 7 - About This Manual

Getting Started 1-7 The adapter uses four status indicators to report its operating status. They can be viewed on the adapter or through the drive c

Página 9 - Getting Started

Chapter 2Installing the AdapterThis chapter provides instructions for installing the adapter in a PowerFlex 40 or PowerFlex 400 drive. This adapter

Página 10 - Features

2-2 Installing the Adapter Setting the MAC AddressSet the MAC address using the MAC Address switches (Figure 2.1). Refer to Table 2.A for specific M

Página 11 - Required Equipment

Installing the Adapter 2-3 8 0 0 0 1 0 0 0 56 0 0 0 1 1 1 09 1 0 0 1 0 0 0 57 1 0 0 1 1 1 010 0 1 0 1 0 0 0 58 0 1 0 1 1 1 011 1 1 0 1 0 0 0 59 1 1

Página 12 - Safety Precautions

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Página 13

2-4 Installing the Adapter Setting the TERM, -BIAS, and +BIAS SwitchesThe adapter’s TERM, -BIAS, and +BIAS switches (Figure 2.2) are used to turn on

Página 14 - Quick Start

Installing the Adapter 2-5 Network with PowerFlex Drives at Starting and/or Ending NodesFor a network with PowerFlex drives at the starting and/or e

Página 15 - Status Indicators

2-6 Installing the Adapter PowerFlex 40 Frames B and C, and PowerFlex 400 Frame C1. Remove power from the drive, and remove the drive cover.2. Use s

Página 16 - 1-8 Getting Started

Installing the Adapter 2-7 4. Connect the Internal Interface cable to the DSI port on the drive and then to the mating DSI connector on the adapter.

Página 17 - Installing the Adapter

2-8 Installing the Adapter PowerFlex 400 Frames D, E, and F1. Remove power from the drive, and open the drive cover.2. Use static control precaution

Página 18 - Setting the MAC Address

Installing the Adapter 2-9 Apply power to the drive. The adapter receives its power from the connected drive. When you apply power to the adapter fo

Página 19 - Installing the Adapter 2-3

2-10 Installing the Adapter Table 2.B Drive and Adapter Start-Up Status Indications Verifying/Setting Key Adapter ParametersFor instructions to u

Página 20 - Reserved for future use

Installing the Adapter 2-11 The following steps in this section assume that the drive will receive the Logic Command and Reference from the BACnet M

Página 21

2-12 Installing the Adapter 5. Insert the 3-pin linear plug into the mating adapter socket.6. Close or install the drive cover.7. Apply power to the

Página 22

Chapter 3Configuring the AdapterThis chapter provides information and instructions for setting the parameters in the adapter. For a list of parame

Página 23 - Installing the Adapter 2-7

Summary of ChangesThe information below summarizes the changes made to this manual since its last release (October 2006): Description of Changes P

Página 24

3-2 Configuring the Adapter Adapter parameters cannot be accessed using the integral keypad on a PowerFlex 4-Class drive. You must use DriveExplorer

Página 25 - Applying Power

Configuring the Adapter 3-3 NOTE: All configuration procedures throughout this chapter use the optional, external PowerFlex 4-Class HIM to access pa

Página 26

3-4 Configuring the Adapter While there are many ways to implement Device Instance and network strategies, the example shown in Figure 3.2 illustrat

Página 27 - -A Signal A TxRxD

Configuring the Adapter 3-5 high portion (most significant digits) of the number and Parameter 12 - [Device Inst Lo] to enter the low portion (alway

Página 28

3-6 Configuring the Adapter By default, when communications are disrupted (for example, a cable is disconnected), the drive responds by faulting if

Página 29 - Configuring the Adapter

Configuring the Adapter 3-7 Setting the Fault Configuration ParametersIf you set Parameter 02 - [Comm Loss Action] to “Send Flt Cfg,” the values in

Página 30 - VALUE LIMITS SEL 

3-8 Configuring the Adapter The value of Parameter 06 - [Baud Rate Cfg] determines the baud rate used by the adapter. The Autobaud setting will dete

Página 31 - Configuring the Adapter 3-3

Configuring the Adapter 3-9 Changes to switch settings and some adapter parameters require that you reset the adapter before the new settings take e

Página 32 - Building Level Network 2

3-10 Configuring the Adapter The following parameters provide information about the status of the adapter. You can view these parameters at any time

Página 33 - Device Instance Number

Chapter 4Using BACnet ObjectsThis chapter provides information about controlling a PowerFlex 4-Class drive using BACnet objects. BACnet nodes are

Página 35 - Setting the Comm Loss Time

4-2 Using BACnet Objects This section describes how to operate a drive on the network using a combination of BACnet object types for basic control.

Página 36 - Setting the Baud Rate

Using BACnet Objects 4-3 The type of drive used on the network determines the specific BACnet objects that are supported. Refer to Table 4.A for des

Página 37 - Resetting the Adapter

4-4 Using BACnet Objects Table 4.A BACnet Object Descriptions and Supported Drives (Continued)Object Name Use This Object to…Compatible PowerFlex

Página 38 - Flash Updating the Adapter

Using BACnet Objects 4-5 Table 4.A BACnet Object Descriptions and Supported Drives (Continued)Object Name Use This Object to…Compatible PowerFlex

Página 39 - Using BACnet Objects

4-6 Using BACnet Objects Table 4.A BACnet Object Descriptions and Supported Drives (Continued)Object Name Use This Object to…Compatible PowerFlex

Página 40 - Clearing a Drive Fault

Chapter 5TroubleshootingThis chapter provides information for diagnosing and troubleshooting potential problems with the adapter and network. The

Página 41 - Supported BACnet Objects

5-2 Troubleshooting PORT Status IndicatorState Cause Corrective ActionsOff The adapter is not powered or is not properly connected to the drive.•

Página 42 - 4-4 Using BACnet Objects

Troubleshooting 5-3 NET A Status IndicatorState Cause Corrective ActionsOff The adapter is not powered or is not properly connected to the network.•

Página 43 - Using BACnet Objects 4-5

5-4 Troubleshooting If you encounter unexpected communications problems, the adapter’s diagnostic items can help you or Rockwell Automation personne

Página 44 - 4-6 Using BACnet Objects

Troubleshooting 5-5 The adapter has an event queue to record significant events that occur in the operation of the adapter. When such an event occur

Página 45 - Troubleshooting

Table of ContentsPreface About This Manual Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P-1Rockwell Automation

Página 46 - MOD Status Indicator

5-6 Troubleshooting 7–9 Reserved —DSI Events10 Slave Detected The adapter detected that the slave has been connected.11 Slave Removed The adapter de

Página 47 - NET B Status Indicator

Appendix ASpecificationsAppendix A presents the specifications for the adapter. Topic PageCommunicationsA-1Electrical A-1Mechanical A-1Environment

Página 48

A-2 Specifications NOTE: The addition of a ferrite core (Fair-Rite P/N 0431167281 or equivalent) to the BACnet cable might be required on applicatio

Página 49 - Viewing and Clearing Events

Appendix BAdapter ParametersAppendix B provides information about the adapter parameters. The parameters in the adapter are numbered consecutively

Página 50 - 5-6 Troubleshooting

B-2 Adapter Parameters 02 [Comm Loss Action]Sets the action that the adapter and drive will take if the adapter detects that network communications

Página 51 - Specifications

Adapter Parameters B-3 06 [Baud Rate Cfg]Sets the baud rate (kilobits per second) at which the adapter communicates. (Updates Parameter 07 - [Baud R

Página 52 - Regulatory Compliance

B-4 Adapter Parameters Notes:

Página 53 - Adapter Parameters

Appendix CProtocol Implementation Conformance Statement (PICS)Date: March 27, 2006Vendor Name: Rockwell AutomationProduct Name: 22-COMM-BProduct Mo

Página 54 - B-2 Adapter Parameters

C-2 Protocol Implementation Conformance Statement (PICS) Standard Object Types SupportedThe table below lists the object types supported by the 22-C

Página 55 - Adapter Parameters B-3

Protocol Implementation Conformance Statement (PICS) C-3 Data Link Layer Options BACnet IP, (Annex J) BACnet IP, (Annex J), Foreign Device ISO 88

Página 56 - B-4 Adapter Parameters

ii Table of Contents Chapter 5 TroubleshootingUnderstanding the Status Indicators . . . . . . . . . . . . . . . . . . . 5-1PORT Status Indicator .

Página 57 - Conformance Statement (PICS)

C-4 Protocol Implementation Conformance Statement (PICS) Notes:

Página 58

Appendix DRouting Capability for Networked DrivesAppendix D provides information about the unique routing capability for up to 127 PowerFlex 4/4M/4

Página 59 - Networking Options

D-2 Routing Capability for Networked Drives Notes:

Página 60

GlossaryA AdapterDevices such as drives, controllers, and computers usually require an adapter to provide a communication interface between them an

Página 61

G-2 Glossary DSI ProductA device that uses the DSI communications interface to communicate with one or more peripheral devices. For example, a motor

Página 62

Glossary G-3 Flash UpdateThe process of updating firmware in a device. The adapter can be flash updated using various Allen-Bradley software tools.

Página 63 - Glossary

G-4 Glossary N NVS (Non-Volatile Storage)NVS is the permanent memory of a device. Devices such as the adapter and drive store parameters and other i

Página 64 - F Fault Action

IndexNumerics3-pin linear plug, 2-11Aadapterapplying power, 2-9commissioning, 2-1compatible products, 1-3components, 1-1connecting to a drive, 2-6c

Página 65 - M MAC Address

Index-2 EEDS (Electronic Data Sheet) filesdefinition/web site, G-2EEPROM, see Non-Volatile Storage (NVS)electrical specifications, A-1environmental

Página 66 - Z Zero Data

Index-3 network cable - connecting to 3-pin plug, 2-11Non-Volatile Storage (NVS)definition, G-4in adapter, 3-1Pparametersaccessing, 3-1configuring,

Página 67 - Numerics

PrefaceAbout This Manual You can view or download publications at http://www.rockwellautomation.com/literature. To order paper copies of technical

Página 68

Index-4 Zzero dataconfiguring the adapter for, 3-6definition, G-4

Página 70

www.rockwellautomation.comAmericas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 4

Página 71

P-2 About This Manual Rockwell Automation, Inc. offers support services worldwide, with over 75 sales/support offices, over 500 authorized distribut

Página 72

Chapter 1Getting StartedThe adapter is intended for installation into a PowerFlex 40 or PowerFlex 400 drive and is used for network communication.

Comentários a estes Manuais

Sem comentários