Rockwell-automation 1762-OA8 Solid State Output Module Manual do Utilizador Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 16
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
10 Solid-State Output Module
Publication 1762-IN007B-EN-P- June 2013
I/O Memory Mapping
Output Data File
For each output module, the output data file contains the controller-directed state of the discrete
output points. Bit positions 0…7 correspond to output terminals 0…7.
w = write only, 0 = always at a 0 or OFF state
A
ddressing
The addressing scheme for 1762 Expansion I/O is shown below.
(1) I/O located on the controller (embedded I/O) is slot 0. I/O added to the controller (expansion I/O) begins with
slot 1.
Word
Bit Position
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
0 0 0 0 0 0 0 0 0 w w w w w w w w
O0:x.0/0
Output
Data File
Slot Number
(1)
Word (always zero for this module)
Bit (0…7)
Bit Delimiter
Word Delimiter
Slot Delimiter