Rockwell-automation 1734-ADNX POINT I/O DeviceNet Adpater User Manual Manual do Utilizador Página 92

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 136
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 91
Publication 1734-UM002C-EN-P - July 2003
B-12 1734-ADNX Quick Start
A window describing Auto Start Mode opens.
Right now, the 1734-ADNX is not in another scanner’s scanlist so
you can use the Auto Start Mode feature. By using Auto Start
Mode, the 1734-ADNX will map all the devices on the Subnet
and automatically adjust the value for parameters 1, 9, 10, 11,
and 12.
2. Select the dropdown box next to parameter 6. You can map the
data using the four options discussed earlier. If you choose to
use the Map Data with Fixed Map Size option, the map size is
selected with parameter 7.
3. For this example, choose Map Data to Word Boundaries as shown
below:
Vista de página 91
1 2 ... 87 88 89 90 91 92 93 94 95 96 97 ... 135 136

Comentários a estes Manuais

Sem comentários