Publication 1734-UM009B-EN-P - July 2003
Configuring Your ASCII Module 2-9
Configuration Assembly
The ASCII modules support a configuration assembly, that is accessed
through the Assembly Object (Class 4), Instance 103. The
configuration assembly is 18 bytes.
Table 2.2 Configuration Assembly
Byte Parameter Parameter Instance
(See Table 2.3)
0 ASCII Serial Character Format 1
1 ASCII Serial Comm Speed 2
2 ASCII Max Number of Receive Characters 3
3 ASCII Receive Record Start Mode 4
4 ASCII Receive Start Delimiter 5
5 ASCII Receive Record End Mode 6
6 ASCII Receive End Delimiter 7
7 ASCII Receive String Data Type 8
8 ASCII Pad Mode 9
9 ASCII Pad Character 10
10 ASCII Receive Swap Mode 11
11 DeviceNet Handshake Mode 12
12 ASCII Max Number of Transmit Characters 17
13 ASCII Transmit End Delimiter Mode 18
14 ASCII Transmit End Delimiter Character 19
15 ASCII Consume String Data Type 20
16 ASCII Transmit Swap Mode 21
17 DeviceNet Record Header Mode 22
Comentários a estes Manuais