1-4
Introduction
Connector Cable
A cable is used to connect the Remote Keypad to the Bulletin 160 Series C drive.
The Keypad can be connected and disconnected when the drive is under power.
Important:
If
P46 - [Input Mode]
is set to 2 or 6, disconnecting the Remote
Keypad will cause the drive to fault.
The following connector cables are available and purchased separately.
160-C10 – 1 meter cable, non-locking
160-C10R – 1 meter cable, non-locking with right angle for minimal depth
160-C30 – 3 meter cable, locking each end
160-C50 – 5 meter cable, locking each end
The 3- and 5-meter connector cables have a locking mechanism to ensure that the
cable will not be disconnected accidentally. The 1-meter connector cables do not
have a locking mechanism. To remove the cable from the drive or the Remote
Keypad, pull back on the plastic housing of the cable connector.
Keypad to Drive Cable Connection Figure 1.5
ATTENTION:
Attaching earth ground to the drive control
common terminal is recommended to improve noise immunity. In
addition, the control common terminal must be grounded if the
Remote Keypad is to be connected or disconnected with the drive
under power. Failure to observe this precaution could result in severe
bodily injury or death.