Meter Port 1
1002 UDC Module Meter Port 1 Register Number Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description:
UDC register number
(o-2044)
to be mapped to meter port 1.
1003 UDC Module Meter Port 1 Bit Number Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description: Bit number of the UDC register specified in register 1002 that is to be mapped to port 1.
Enter a value of 100 (bit 00) to 115 (bit 15) as required. Enter a value of zero if all of the register’s bits
are to be displayed.
1004 UDC Module Meter Port 1 Maximum Value Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description:
Set this register to the number that will represent + 1 OV. The maximum allowable value
is 32767.
1005 UDC Module Meter Port 1 Minimum Value Register
Hex Value:
N/A
Sug. Var. Name:
N/A
Range:
N/A
Access:
Read/Write
UDC Error Code:
N/A
LED:
N/A
Description: Set this register to the number that will represent -1 OV. The minimum allowable value
is -32768.
3-44