Configuring FactoryTalk Historian for Batch Chapter 2
The following instructions explain how to initialize the database
schema for FactoryTalk Historian for Batch. Complete these steps
after you have installed the RSBizWare software:
1. Configure the Information Services Manager. (See the
RSBizWare Configuration Assistant in the Service Console
for instructions.)
When the core RSBizWare database has been successfully
initialized, the traffic light icon displays a green light to
indicate that the server is running.
2. Stop the Information Services Manager. In the Service
Console, right-click the name of your Information Services
Manager, and from the pop-up menu, select Stop Server.
The traffic light icon displays a red light when the server is
stopped.
3. Run the RSBizWare Database Wizard. In Windows Explorer,
navigate to C:\Program Files\Rockwell
Software\RSCommon\DBLoadWiz.exe. Double-click
DBLoadWiz.exe to start the RSBizWare Database Wizard.
4. On the Welcome dialog box, click Next.
Initializing the RSBizWare
Database On SQL Server
Rockwell Automation Publication BHIST-UM011A-EN-E-June 2014 15