Rockwell-automation Discrete Machine Performance Solution Manual do Utilizador Página 22

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 21
DISCRETE MACHINE PERFORMANCE SOLUTION USERS GUIDE
16
• • • • •
5. Gradually tighten the clips one at a time around the bezel using the specified
sequence. Note that the sequence begins with the center clips and continues to the
corner clips.
Repeat this process at least three times until the clips are hand-tight and the gasket is
compressed uniformly against the panel.
Tighten mounting clips to a torque of 10 in-lbs (1.1 N•m) in the sequence shown
above. Do not over-tighten.
Connecting a keyboard and pointing device
A keyboard and pointing device can be plugged individually into the PS/2 port on the
bottom of the computer. There are separate PS/2 ports for the keyboard and the pointing
device.
Tighten mounting clips to a torque of 10 in-lbs (1.1 N•m) to provide a proper seal and prevent
damage to the VersaView computer. Rockwell Automation assumes no responsibility for
water or chemical damage to the terminal or other equipment within the enclosure because
of improper installation.
Discrete.book Page 16 Wednesday, December 8, 2004 2:22 PM