4–17OCI Data Server Data Items
Publication 8520-6.6 - August 1999
Enumeration Result:
0 Short
1 Unsigned Short
2 Long
3 Unsigned Long
4 Quad
5 Unsigned Quad
6 Float
7 Double
8 Unsigned Character
9 ASCII Character
For example:
AMP_PARAMETER_DATA_TYPE,1
returns the data type enumeration for patch AMP parameter number
1. Use AMP_PARAMETER_NUMBER to identify the actual AMP
parameter associated with patch AMP parameter number 1.
AMP_PARAMETER_NUMBER patchAMP_num
Data Type UINT
Read/Write Read
Array Index patchAMP_num
Control Type Lathe/Mill/Grinder
1
1
Grinder Control Type is not available for Release 1 of 9/PC.
This data item is used to identify quick edit number of a specific
patchAMP parameter. For example:
AMP_PARAMETER_NUMBER, 1
returns the value 11 indicating that AMP parameter with the quick
edit number of 11 is the first patch AMP parameter.
NUM_PATCHABLE_AMP_PARAMETERS
Data Type UINT
Read/Write Read
Array Index patchAMP_num
Control Type Lathe/Mill/Grinder
1
1
Grinder Control Type is not available for Release 1 of 9/PC.
This data item is used to identify the quantity of available AMP
parameters that can be changed thru patch AMP. For example if the
value of NUM_PATCHABLE_AMP_PARAMETERS is 299 it
indicates that the patch AMP numbers range from 1 to 299. Use this
to identify the range for the patchAMP_num argument for the items
AMP_PARAMETER_NUMBER, and
AMP_PARAMETER_DATA_TYPE.