OCI Data ItemsA–10
Publication 8520-6.6. - August 1999
Control TypeReqDual
Proc.
Units
Dependency
UnitsArray IndicesNum
Indices
OCI/9/PCData TypeDescriptionItem (Name)
93
TOOL_LENGTH_GEOM_
OFFSETS
Tool Length Geometry Offset LREAL [ ] [ ] Both 2 Offset Num, Num
Axes
Inch/Met
ric/De
grees
TOOL_ENTRY_UN
ITS [ Tool_number
]
Yes R/W Lathe, Mill
92
TOOL_LENGTH_WEAR_
OFFSETS
Tool Length Wear Offset LREAL [ ] [ ] Both 2 Offset Num, Num
Axes
Inch/Met
ric/De
grees
TOOL_ENTRY_UN
ITS [ Tool_number
]
Yes R/W Lathe, Mill
98
TOOL_ORIENTATION Tool Orientation Direction INT [ ] Both 1 Offset Num Yes R/W Lathe, Grinder
95
TOOL_RADIUS_GEOM_
OFFSETS
Tool Radius Geometry Offset LREAL [ ] Both 1 Offset Num Inch/Met
ric/De
grees
TOOL_ENTRY_UN
ITS [ Tool_number
]
Yes R/W Lathe, Mill
94
TOOL_RADIUS_WEAR_
OFFSETS
Tool Radius Wear Offset LREAL [ ] Both 1 Offset Num Inch/Met
ric/De
grees
TOOL_ENTRY_UN
ITS [ Tool_number
]
Yes R/W Lathe, Mill
96
WHEEL_GEOM_OFFSETS Wheel Geometry Offset LREAL [ ] [ ] Both 2 Offset Num, Num
Axes
Inch/Met
ric/De
grees
TOOL_ENTRY_UN
ITS [ Tool_number
]
No R/W Grinder
l
Operating Mode
46
ACTIVE_MODE Active Mode UINT enumerated
PAL
Both 0 Yes R All Controls
50
ACTIVE_SCALE_INDICATOR Active Scaling Indicator on Scaled Axes DINT Both 0 Yes R All Controls
31
ACTIVE_UNITS Inch/Metric Mode UINT enumerated Both 0 Yes R All Controls
54
AXIS_RAD_DIA_MODE Axis Radius/Diameter mode DINT bit pattern Both 0 Yes R Lathe/Cyl
m
PAL/Logic Data
%...................
I/O Variables (%variables) UINT [ ]
OCI
No PAL
Prot
All Controls
!.......................
User defined PAL globals (!variables) UINT [ ]
OCI
No PAL
Prot
All Controls
$......................
System defined PAL globals ($variables) UINT [ ]
Both
PAL
Spec
PAL
Prot
All Controls
298
BLOCK_TRANSFER_READ_ DATA
Block transfer read data ($ARST) INT [ ]
OCI
1 MAX_BLOCK_TRANSFER No R All Controls
299
BLOCK_TRANSFER_WRITE_ DATA
Block transfer write data ($AWST) INT [ ]
OCI
1 MAX_BLOCK_TRANSFER No R All Controls
152
FG_CRITICAL_AVERAGE Critical Foreground Average UINT OCI 0 usec No R All Controls
153
FG_CRITICAL_MAX Critical Foreground Maximum UINT OCI 0 usec No R All Controls
154
FG_TOTAL_AVERAGE Total Foreground Average UINT OCI 0 usec No R All Controls
155
FG_TOTAL_MAX Total Foreground Maximum UINT OCI 0 usec No R All Controls
192
MEMORY_DUMP_ADDRESS Memory dump start address
(debug monitor)
DINT OCI 0 No R/W All Controls
Comentários a estes Manuais