Rockwell-automation 57RF RFID ICODE Handheld Interface User Manual Manual do Utilizador Página 97

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 96
Rockwell Automation Publication 57RF-UM001A-EN-P - September 2011 97
Chapter 8
Parameters
The RFID ICODE handheld interface will return the following error codes if an
error occurs while passing function parameters:
Read/Write
The RFID ICODE handheld interface will return the following error codes if an
error occurs while attempting to read, write, clear or lock tag data:
Value Description
200 Invalid flag setting
201 Invalid tag type
202 Tag ID is empty
203 Invalid tag type for read/write command
204 Invalid starting block (starting block range is 0…249)
205 Invalid number of data blocks (data block range is 1…16)
206 Tag data is empty
207 Data byte size cannot be less than one
208 Invalid sector number
209 Invalid key length
210 Invalid key type
211 Invalid function type
212 Invalid data (data range must be 0…255)
Value Description
–1 No tag present
–2 Invalid start block or length
–3 Tag ID mismatch
–4 User cancelled
–5 Invalid tag info read
300 No tag ID found in RF field
301 Not a valid tag ID, invalid tag type detected
302 Could not read tag data
303 Invalid starting block (starting block range is 0…249)
304 Invalid number of data blocks
305 Could not set reader command
306 Could not write tag data
307 Invalid message length
308 Could not lock data blocks or data blocks already locked