Rockwell Automation Publication 57RF-UM001A-EN-P - September 2011 95
Chapter
8
Troubleshooting
Frequently Asked
Questions
My RFID ICODE handheld interface does not respond when I press the
power button.
Is the unit in Suspend mode?
If battery-powered, check the batteries.
Are all cables connected properly:
Is the power supply plugged into an active AC outlet?
Is the power connector securely plugged into the RFID ICODE
handheld interface?
I changed my system settings, but when I turn on the RFID ICODE
handheld interface, my settings are gone.
You must save the registry after making any system or configuration
changes. See Manually Saving the Persistent Registry
on page 36.
I transferred files to the RFID ICODE handheld interface from my host
computer, but when I turn on the RFID ICODE handheld interface my
transferred files are missing.
To store transferred files permanently, you must file copy the files into
internal flash memory or a compact flash card.
Occasionally, transferred files can be hidden from view, double-click My
Computer, select Options from the View menu and clear all boxes.
I cannot connect to the development system using ActiveSync.
Did you install ActiveSync using the Administrator account?
Check the cable connections.
Check the serial communications configuration.
Make sure the correct COM port is available.
In ActiveSync, check the Connection Settings for the connection type you
are using (USB, Serial or Ethernet).
The screen is too light or too dark.
Adjust the brightness via the brightness control in the Control Panel.
The stylus is not responding properly.
The screen is not calibrated correctly to interpret the screen taps. You need
to recalibrate the screen.