Appendix A
Color CVIM Communications with MATH-PAK Installed
A9
Table A.7
Configuration blocks (even numbered, 110156) for formulas 18, 1724, 3340
(windows 124) fault and warning ranges
Remote I/O
& RS232
Word #
Bit # Definition Usage Notes
15 015 Fault Range High (Integer)
Words 15 and 16 represent a 16 (bit).16 (bit)
fixed point decimal value or 32 bit integer.
16 015 Fault Range High (Fraction)
17 015 Fault Range Low (Integer)
Words 17 and 18 represent a 16 (bit).16 (bit)
fixed point decimal value or 32 bit integer.
18 015 Fault Range Low (Fraction)
19 015
Warning Range High
(Integer)
Words 19 and 20 represent a 16 (bit). 16 (bit)
fixed point decimal value or 32 bit integer.
20 015
Warning Range High
(Fraction)
21 015
Warning Range Low
(Integer)
Words 21 and 22 represent a 16 (bit).16 (bit)
fixed point decimal value or 32 bit integer.
22 015
Warning Range Low
(Fraction)
23 015 Reserved
Configuration blocks 110-156 (even-numbered) provide the fault and
warning range information for windows 124, respectively, if no
corresponding formulas are enabled. If formulas are enabled, the fault and
warning ranges for the enabled formulas will replace the ranges for
corresponding windows in the configuration blocks. For a listing of
configuration blocks for corresponding formulas and tools, refer to
Table A.5, page A7.
Formula contents: The contents of the defined formulas are stored in
blocks in a portion of Color CVIM memory referred to in the Color CVIM
Communications Manual as template memory. In order to transfer the
formula content information, you must set the discrete bits for template block
transfer (refer to, in the Color CVIM Communications Manual, Table 4.C,
Word 23, Block Transfer Type bits).
The Color CVIM communications manual lists and describes all of the
accessible discrete bits. The discrete bit information for an enabled formula
(fault and warning range flags) will replace the discrete bit information for a
corresponding gage or window, as shown in Table A.8, beginning on page
A10.