Installation Instructions
PowerFlex
®
DC Drive - Frame C Transient Noise
Filter Circuit Board Fuse Replacement
What This Kit Includes
Three 6x32mm, 25A 500V fuses
Static Strap
What You Need to Do
The Transient Noise Filter circuit board is located near the bottom of
the drive, behind the Control EMI shield. You must move the Control
EMI shield that holds the Control board in order to access the Transient
Noise Filter board and fuses.
1. Remove and lock-out all incoming power to the drive.
!
ATTENTION: To avoid an electric shock hazard, ensure that
all power to the drive has been removed before performing the
following.
Transient Noise Filter circuit board
L1 L2 L3
O
I
Vista de página 0
1 2 3 4 5 6

Resumo do Conteúdo

Página 1 - PowerFlex

Installation InstructionsPowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board Fuse Replacement What This Kit Includes• Three 6x32mm, 25

Página 2

2 PowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board Fuse Replacement 2. Disconnect the DPI cable from the HIM assembly (if present).3

Página 3 - Control board

PowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board Fuse Replacement 3 5. Disconnect the HIM Communication cable from the connector on

Página 4 - Remove cable

4 PowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board Fuse Replacement 7. Loosen the two captive screws at the top of the Control EMI s

Página 5 - Remove fuses from holders

PowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board Fuse Replacement 5 9. Remove the three fuses from the fuse holders (F11, F21 and F3

Página 6

Publication 20P-IN042A-EN-P - March 2009Copyright © 2008 Rockwell Automation. All rights reserved. Printed in USA.www.rockwellautomation.comAmericas: