Overview
The purpose of this insert instructions manual is to provide the special information
about the custom firmware.
This custom firmware option adds support for the maximal output frequency [Drive Speed]
up to 300 Hz, and quick stop DC braking function.
About Parameters
Compared to the standard firmware, the custom firmware has added the following new
parameters, changed the following standard parameters. During configuration and
parameters programming, it should pay attention.
P032 [Motor NP Hertz]
Values
Default 60 Hz
Min/Max: 10/300 Hz
Display: 1 Hz
P034 [Minimum Freq]
Values
Default 0.0 Hz
Min/Max: 0.0/300.0 Hz
Display: 0.1 Hz
ATTENTION: The Custom Firmware supplied is designed for a
specific application and load condition. It differs from the standard
PowerFlex4 product offering and must be installed and run only under
this custom application. Attempting to run this Custom Firmware under
any other type of application, could result in unpredictable and/or
hazardous conditions.
ATTENTION: The
drive
contains
ESD
(Electrostatic Discharge)
sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing this assembly.
Component damage may result if ESD control procedures are not
followed. If you are not familiar with static control procedures, reference
A
-
B publication 8000
-
4.5.2, “Guarding Against Electrostatic Damage”
PowerFlex 4 Custom Firmware
DA” Option – 300 Hz Maximum Frequency and Quick Stop (EBM)
Instructions
Vista de página 0
1 2 3 4

Resumo do Conteúdo

Página 1 - PowerFlex 4 Custom Firmware

Overview The purpose of this insert instructions manual is to provide the special information about the custom firmware. This custom firmware op

Página 2 - Parameters Settings

P035 [Maximum Freq] Values Default 60 Hz Min/Max: 0/300.0 Hz Display: 1 Hz A069 [Internal Freq] Values Default 60.0 Hz Min/Max: 0.0/300.0 Hz

Página 3

PowerFlex 4 Custom Firmware 3 P042 [Initial Braking Pressure] It is adjustable from 80 (minimum initial braking pressure) to 2000 (ma

Página 4

Publication 22A-IN003A-EN-E - July 2004Copyright © 2004 Rockwell Automation. All rights reserved. Printed in Switzerland.