16 Input/16 Output Digital and 2 Input/2 Output Analog Embedded I/O Boards 19
Publication 1799-IN011A-EN-P - February 2007
Calibrate Your Analog Inputs and Outputs
Follow the example calibrations shown below to learn how to calibrate your card.
Input Calibration
The wiring method decides the operating mode of current or voltage inputs. Calibration data
of both voltage and current are stored in nonvolatile memory and selected according to the
parameter value of AI INPUT RANGE.
Example current calibration of channel 0
Perform the following steps to calibrate your current input.
1. Set input channel range to 0…20 mA.
2. Select the input channel.
3. Send command to Begin Calibration.