Rockwell-automation 1784-PM16SE SoftLogix Motion Card Setup and Config Manual do Utilizador Página 61

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 60
Publication 1784-UM003A-EN-P – June 2003
Adding and Configuring Your 1784-PM02AE Motion Module 53
The name must be IEC 1131-3 compliant. If you attempt to enter an invalid
character or exceed the maximum length, the software beeps and ignores the
character.
Description
Enter a description for the module here, up to 128 characters. You can use any
printable character in this field. If you exceed the maximum length, the
software beeps to warn you, and ignores any extra characters.
Slot
Enter the slot number where the module resides. The spin button contains
values that range from 0 to 1 less than the chassis size (e.g., if you have a 4-slot
chassis, the spin button will spin from 0 to 3). If you enter a slot number that
is out of this range, you will receive an error message when you go to apply
your changes.
The slot number cannot be changed when online.
Revision
Select the minor revision number of your module.
The revision is divided into the major revision and minor revision. The major
revision displayed statically is chosen on the Select Module Type dialog.
Electronic Keying
Select one of these keying options for your module during initial module
configuration:
Exact Match - all of the parameters must match or RSLogix rejects the
inserted module.
Vendor
Product Type
Catalog Number
Major Revision
Minor Revision
Compatible Module
the Module Types, Catalog Number, and Major Revision must match
the Minor Revision of the physical module must be equal to or
greater than the one specified in the software or RSLogix 5000 will
reject the inserted module.
Disable Keying - RSLogix 5000 will not employ keying at all.
Vista de página 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 450 451

Comentários a estes Manuais

Sem comentários