Rockwell-automation 1771-IFF/A INSTL.INSTR FAST ANALOG INPUT Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 1771-IFF/A INSTL.INSTR FAST ANALOG INPUT. Rockwell Automation 1771-IFF/A INSTL.INSTR FAST ANALOG INPUT User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
1 Publication 1771-IN046B-EN-P - December 2003
Installation Instructions
Fast Analog Input Module
Cat. No. 1771-IFF Series A
Contents
Use this document as a guide when installing the 1771-IFF series A fast analog
input module.
Important User Information
Solid state equipment has operational characteristics differing from those of
electromechanical equipment. Safety Guidelines for the Application, Installation and
Maintenance of Solid State Controls (Publication SGI-1.1 available from your local
Rockwell Automation sales office or online at http://www.ab.com/manuals/gi)
describes some important differences between solid state equipment and hard-wired
electromechanical devices. Because of this difference, and also because of the wide
variety of uses for solid state equipment, all persons responsible for applying this
equipment must satisfy themselves that each intended application of this equipment is
acceptable.
In no event will Rockwell Automation, Inc. be responsible or liable for indirect or
consequential damages resulting from the use or application of this equipment.
The examples and diagrams in this manual are included solely for illustrative purposes.
Because of the many variables and requirements associated with any particular
installation, Rockwell Automation, Inc. cannot assume responsibility or liability for
actual use based on the examples and diagrams.
No patent liability is assumed by Rockwell Automation, Inc. with respect to use of
information, circuits, equipment, or software described in this manual.
To See page
Important User Information 1
North American Hazardous Location Approval 4
Understand Product Compatibilty 5
Calculate Power Requirements 6
Determine Module Placement in the I/O Chassis 6
Set the Simulation Jumper 7
Set the Configuration Jumpers 7
Key the Backplane Connector 8
Install the Module and Field Wiring Arm 8
Connect Wiring to the Field Wiring Arm 9
Grounding 13
Configure the Module 14
Interpret Status Indicators 16
Troubleshooting 17
Specifications 18
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Fast Analog Input Module

1 Publication 1771-IN046B-EN-P - December 2003Installation InstructionsFast Analog Input ModuleCat. No. 1771-IFF Series AContentsUse this document as

Página 2 - ATTENTION

Publication 1771-IN046B-EN-P - December 200310 Fast Analog Input ModuleInput connections for the 1771-IFF with:• single-ended inputs are shown on

Página 3 - Environment and Enclosure

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 11– Jumper all unused channels to modulecommon to reduce noise.Channel 1Chann

Página 4 - AVERTISSEMENT

Publication 1771-IN046B-EN-P - December 200312 Fast Analog Input Moduledifferential wiringFunctional Ground– Unused channels must have their + an

Página 5

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 13GroundingWhen using shielded cable wire, ground the foil shield and drain w

Página 6 - Placement in the I/O

Publication 1771-IN046B-EN-P - December 200314 Fast Analog Input ModuleConfigure the ModuleYou must configure the module to conform to the analog

Página 7 - Set the Configuration

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 15Use the following table to read data from your input module.Dec. Bits 15 14

Página 8

Publication 1771-IN046B-EN-P - December 200316 Fast Analog Input ModuleWhen Data Format bits 9 and 10 in block transfer write word 3 are set for “

Página 9

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 17TroubleshootingPossible module fault causes and corrective action is descri

Página 10 - Cable Lengths

Publication 1771-IN046B-EN-P - December 200318 Fast Analog Input ModuleSpecificationsDescription ValueInputs per module 16 single-ended; 8 differe

Página 11

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 19ShockOperating Non-operatingIEC 60068-2-27 (Test Ea, Unpackaged Shock)30g p

Página 12 - Functional Ground

Publication 1771-IN046B-EN-P - December 20032 Fast Analog Input ModuleReproduction of the contents of this manual, in whole or in part, without wr

Página 13 - Grounding

Publication 1771-IN046B-EN-P - December 2003 20 PN 957859-99Supersedes Publication 1771-5.46 - May 1996 Copyright © 2003 Rockwell Automation, Inc. All

Página 14 - Configure the Module

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 3ATTENTIONEnvironment and EnclosureThis equipment is intended for use in a Po

Página 15

Publication 1771-IN046B-EN-P - December 20034 Fast Analog Input ModuleNorth American Hazardous Location ApprovalThis 1771-IFF series A module is h

Página 16 - Interpret Status Indicators

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 5Understand Product CompatibiltyThe 1771-IFF module can be used with any 1771

Página 17 - Troubleshooting

Publication 1771-IN046B-EN-P - December 20036 Fast Analog Input ModuleCalculate Power RequirementsThe module receives its power through the 1771 I

Página 18 - Specifications

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 7Set the Simulation JumperThe module is shipped with the simulation jumper se

Página 19 - Description Value

Publication 1771-IN046B-EN-P - December 20038 Fast Analog Input ModuleKey the Backplane ConnectorPlace your module in any slot in the chassis exce

Página 20 - Rockwell Automation Support

Publication 1771-IN046B-EN-P - December 2003Fast Analog Input Module 9Connect Wiring to the Field Wiring ArmConnect your I/O devices to the cat. n

Comentários a estes Manuais

Sem comentários