3-40
SMC Dialog Plus Smart Motor Controller
Control Options (cont.)
Accu-Stop Option (cont.)
Figure 3.30 Accu-Stop Option Sequence of Operation
Slow Speed Start Select “On.
When Accu-Stop push button is closed, start/stop function is disabled.
Motor
Speed
100%
Push Button
Start
Stop
Accu-Stop
Auxiliary
Contacts
Norma
Up-to-speed
Open
Open
Open
Closed
Closed
Closed
Start
Run
Slow
Speed
Accu-Stop
Braking
Slow Speed
Braking/Coast
Time (seconds)
If Coast-to-rest Selected.
Slow Speed
Slow
Speed
Braking
!
ATTENTION: The user has the ultimate responsibility
to determine which stopping mode is best suited to th
application and will meet applicable standards for
operator safety on a particular machine.