Rockwell-automation Logix5000 Controllers Add-on Instructions Programm Manual do Utilizador Página 80

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 104
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 79
Chapter 3 Using Add-On Instructions
5. In the routine that that includes the Add-On Instruction, create another
module reference parameter.
1. In the routine, right-click Parameters and Local Tags and then click
New Parameter.
2. Enter the following values in the dialog box.
Attribute Value
Name ModuleRef_Slot01
Usage InOut parameter
Data Type MODULE
3. Click the down arrow in the Parameter Connections box, and choose
a hardware module. This is the module that the parameter references.
6. Add the Add-On Instruction to the routine.
7. Connect the routine's module reference parameter to the Add-On
Instruction's module reference parameter. Double-click the question mark
next to the Add-On Instructions module reference parameter, then click
80 Rockwell Automation Publication 1756-PM010F-EN-P - October 2014
Vista de página 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 103 104

Comentários a estes Manuais

Sem comentários