DC3E Non-Regenerative DC Drive
User Guide
1/4 to 2 HP, 115/230 VAC
Instruction Manual D2-3452-1
M/N DC3N-12D-00-010-AI
M/N DC3N-12D-4X-010-AI
250-0287-rev2.qxd 3/12/01 10:27 AM Page a
Vista de página 0
1 2 3 4 5 6 ... 91 92

Resumo do Conteúdo

Página 1 - M/N DC3N-12D-4X-010-AI

DC3E Non-Regenerative DC DriveUser Guide1/4 to 2 HP, 115/230 VACInstruction Manual D2-3452-1M/N DC3N-12D-00-010-AIM/N DC3N-12D-4X-010-AI250-0287-rev2.

Página 2

Minimum Speed Trimpot Range (% of rated voltage) 0to50%Torque Trimpot Maximum Setting (% of maximum current) 200%IR Drop Compensation (% of rated arma

Página 3

Drive RatingsDC Motor MotorRated DC Armature Field FieldMotor AC Line Input Armature Current Voltage CurrentHP Amps KVA Voltage (Amps) (Amps)1/4 4.5 0

Página 4

4Dimensions and LayoutFigure 1. DC3N-12D-00-010-AI Dimensions250-0287-rev2.qxd 3/12/01 10:27 AM Page 4

Página 5 - Contents

5DimensionsTHREE 0.88 [22] KNOCKOUTSALL DIMENSIONS IN INCHES [MILLIMETERS]Figure 2. DC3N-12D-4X-010-AI Dimensions250-0287-rev2.qxd 3/12/01 10:27 AM Pa

Página 6

6 Dimensions and LayoutFigure 3. PC Board Layout250-0287-rev2.qxd 3/12/01 10:27 AM Page 6

Página 7

7InstallationATTENTION: Only qualified technical personnel,familiar with the construction and operation of thisequipment and the hazards involved, sho

Página 8 - Illustrations

Wiring8 InstallationATTENTION: Circuit potentials are at 115 or 230VAC above ground. To prevent the risk of injury orfatality, avoid direct contact wi

Página 9 - Specifications

9Installation*Reliance Electric considers this an unfavorable condition and does notrecommend bundling power and logic leads for any length.ATTENTION:

Página 10 - Service Conditions

10 InstallationMountingProtect the drive from dirt, moisture, and accidentalcontact. Provide sufficient room for access to the terminalblock and calib

Página 11 - Drive Ratings

The chassis units do not have to be earth grounded. If youchoose to ground the chassis, use a star washer beneath thehead of at least one of the mount

Página 12 - Dimensions and Layout

Trademarks not belonging to Rockwell Automation are property of their respective companies. ©2001 Rockwell International Corporation All rights reserv

Página 13 - 5Dimensions

12 InstallationATTENTION: Most code requires that upstreambranch protection be provided to protect input powerwiring. Failure to observe this precauti

Página 14 - Figure 3. PC Board Layout

13InstallationLine fusingThis DC3 drive model has 15-amp line fuses preinstalledon fuse holders 501 and 502 (FU501 and FU502). Whenreplacing the line

Página 15 - Installation

14Figure 4. Speed Adjust PotentiometerInstallationSpeed adjust potentiometerInstall the circular insulating disk between the mountingpanel and the 10K

Página 16 - 8 Installation

15Alternate speed adjust potentiometer connectionsAlternate speed adjust potentiometer connections may befound in the Application Notes section of thi

Página 17 - 9Installation

16Cage-clamp terminalsLogic connections are made to cage-clamp terminals. Toinsert a wire into the cage-clamp terminal:Figure 5. Cage-Clamp TerminalIn

Página 18 - Chassis drive

17InstallationATTENTION: Do not connect this equipment withpower applied. Failure to follow this directive mayresult in fire or serious injury.ATTENTI

Página 19 - 11Installation

18 InstallationATTENTION: Installation of a master power switch inthe input line is required. This is the only way todisconnect power from the motor.

Página 20 - 12 Installation

19InstallationConnect a motor to terminals A1 and A2 as shown inFigure 6 (page 23). Ensure that the motor voltage rating isconsistent with the drive’s

Página 21

20 InstallationATTENTION: Do not make any connections to F1 andF2 when using a permanent magnet motor. The fieldoutput is for shunt wound motors only.

Página 22

21START/STOP pushbuttonsInstallationPushbutton operation of the DC3N drive requires that a(momentarily) normally-closed STOP pushbutton be wiredto ter

Página 23

iATTENTION: Only qualified personnel familiar with theconstruction and operation of this equipment and thehazards involved should install, adjust, ope

Página 24 - Figure 5. Cage-Clamp Terminal

22 InstallationUsing tachometer feedback improves speed regulation fromapproximately 1% of motor base speed to approximately0.1% of motor base speed.

Página 25 - 17Installation

Figure 6. Chassis Drive Connections23InstallationNOTES1. L1 IS THE HOT TERMINAL.2. L2/115 IS THE NEUTRAL TERMINAL FOR 115 VAC INPUT.3. L2/230 IS THE N

Página 26 - 18 Installation

24 InstallationFigure 7. Chassis Drive Signal Follower ConnectionVoltage or current followerInstead of using a speed adjust potentiometer, these DC3Nm

Página 27 - 19Installation

25Enclosed driveMountingThe NEMA 4X enclosed drive comes with 0.88 inch (22mm) conduit knockout holes at the bottom of theenclosure. The units may be

Página 28 - 20 Installation

266. Turn the slotted screw clockwise until tight to secure thefront cover.7. Set the POWER switch to the OFF position beforeapplying the AC line volt

Página 29

27InstallationConnectionsATTENTION: A single fault like a power device shortmay cause motor rotation when in the stop mode. Theuser is responsible for

Página 30 - 22 Installation

28 InstallationMotorATTENTION: To provide the motor with overloadprotection, local, national, and international codes (e.g.,NEC/CEC) require that a mo

Página 31 - 23Installation

29InstallationPower inputConnect the AC line power leads to terminals L1 and L2 asshown in Figure 8 (page 31). Ensure that earth ground isconnected to

Página 32 - 24 Installation

30 InstallationUsing tachometer feedback improves speed regulation fromapproximately 1% of motor base speed to approximately0.1% of motor base speed.

Página 33 - Enclosed drive

31InstallationFigure 8. Enclosed Drive ConnectionsNOTES1. L1 IS THE HOT TERMINAL.2. L2/115 IS THE NEUTRAL TERMINAL FOR 115 VAC INPUT.3. L2/230 IS THE

Página 34

ii Safety WarningsATTENTION: Starting and stopping with the start/stopterminals does not disconnect AC power in the stopposition. A hardwired AC power

Página 35 - 27Installation

32 InstallationVoltage or current followerInstead of using a speed adjust potentiometer, these DC3Nseriesdrivesmaybewiredtofollowanexternalinputsignal

Página 36 - 28 Installation

33InstallationSlide switchesSee Figure 9 on page 35 for all slide switch locations.LINE VOLTAGE (SW501 and SW502)Select the appropriate line voltage:

Página 37 - 29Installation

34 InstallationATTENTION: The DC3N does not have tachometerloss or a field loss protection. Loss of field ortachometer will cause the motor to run at

Página 38 - 30 Installation

35Figure 9. Slide SwitchesInstallation250-0287-rev2.qxd 3/12/01 10:27 AM Page 35

Página 39 - 31Installation

36OperationATTENTION: Change voltage switch settings onlywhen the drive is disconnected from AC line voltage.Make sure both switches are set to their

Página 40 - 32 Installation

37OperationBefore applying power (all models)ATTENTION: If the motor or drive does not performas described, disconnect the AC line voltageimmediately.

Página 41 - Slide switches

38 OperationDrive operationChassis drive operationPOWER ON startSPEED REFERENCE: External signal orpotentiometerSTART/STOP control: POWER ON/OFFIMPORT

Página 42 - 34 Installation

393. Slowly increase the speed reference signal. The motorslowly accelerates as the potentiometer is turned CWor the external speed reference is incre

Página 43 - Figure 9. Slide Switches

2. Apply AC line voltage.3. Slowly increase the speed reference signal and press theSTART pushbutton. The motor accelerates as thepotentiometer is tur

Página 44 - Operation

41OperationAlternate Starting and Stopping MethodsATTENTION: The DC3 Drive is intended to operateat a predetermined minimum speed. If the applicationr

Página 45 - 37Operation

Specifications 1Dimensions and Layout 4Installation 7Wiring ...8Shielding guidelines ...

Página 46 - Drive operation

42 OperationFigure 10. Run/Decelerate to Minimum Speed SwitchMinimum speedThe circuit shown in Figure 10 may be used to decelerate amotor to a minimum

Página 47

43OperationDynamic braking may be used to rapidly stop a motor(Figure 11, page 44). For the RUN/BRAKE switch, use atwo-pole, two-position switch rated

Página 48 - 40 Operation

44 OperationFigure 11. Dynamic Brake ConnectionDC3N DRIVETable 4. Minimum Recommended Dynamic BrakeResistor ValuesMotor Armature Minimum MinimumCurren

Página 49 - 41Operation

45OperationEnclosed drive operating modesThe mode selector switch on the drive, mounted on itscover, provides the option of operating in either MANUAL

Página 50 - 42 Operation

46 OperationATTENTION: For frequent starts and stops, short theinhibit terminals, decelerate to a minimum speed, orapply a dynamic brake to the motor.

Página 51 - 43Operation

47OperationTo run the motor:1. Set the speed adjust potentiometer to “0” (full CCW).2. Apply AC line voltage.3. Set the POWER switch to the ON positio

Página 52 - Resistor Values

48These DC3N drives have seven user adjustable trimpots.Each drive is factory calibrated to its maximumhorsepower rating. Readjust the calibration tri

Página 53 - 45Operation

49CalibrationFigure 12. Calibration Trimpot LayoutCURRENTLIMITIR COMPTACH VOLTSMAXIMUMSPEEDMINIMUMSPEEDACCELERATIONDECELERATION250-0287-rev2.qxd 3/12/

Página 54 - 46 Operation

Drive Calibration ProcedurePrepare the DC3N drive for calibration as follows. Thisprocedure applies to both chassis and enclosed drives.1. Ensure that

Página 55 - 47Operation

51IMPORTANT: If you run the drive in AUTO mode, youmust recalibrate the MIN SPD trimpot to offset any motordrift caused by the input signal.The MIN SP

Página 56 - Calibration

Field output . . ...29Tachometer feedback ...30Voltage or current follower ...

Página 57 - ACCELERATION

52 CalibrationMAX SPDThe MAX SPD setting determines the motor speed whenthe speed adjust potentiometer or external reference signalis set for maximum

Página 58 - Drive Calibration Procedure

53CalibrationCURRENT LIMITATTENTION: Although the CURRENT LIMITtrimpot is set to 120% of the maximum drive currentrating, continuous operation at that

Página 59

6. Adjust the CURRENT LIMIT trimpot slowly CW untilthe armature current is 120% of motor rated current.7. Set the speed adjust potentiometer or extern

Página 60 - 52 Calibration

55CalibrationApproximate IR COMP calibration:If the motor does not maintain set speed as the loadchanges, gradually rotate the IR COMP trimpot CW. If

Página 61 - 53Calibration

DECELThe DECEL setting determines the time the motor takes toramp to lower speed, within the limits of available torque.The DECEL setting is factory s

Página 62 - 54 Calibration

57CalibrationIMPORTANT: Calibrate the TACH VOLTS setting onlywhen a tachometer is used. The TACH VOLTS setting, likethe IR COMP setting, determines th

Página 63 - 55Calibration

3. Set switch 505 (SW505) to ARM for armaturefeedback.4. Apply power to drive.5. Set the speed adjust potentiometer or externalreference signal to max

Página 64 - 56 Calibration

59CalibrationFigure 13. Typical CURRENT LIMITand IR COMP Settings for DC3N drive(actual settings may vary with each application)250-0287-rev2.qxd 3/12

Página 65 - 57Calibration

60This section shows typical chassis drive connections.Multiple fixed speedsReplace the speed adjust potentiometer with series resistorswith a total s

Página 66 - 58 Calibration

61Application NotesFigure 15. Adjustable Fixed Speeds UsingPotentiometers in SeriesAdjustable speeds using potentiometers inseriesReplace the speed ad

Página 67 - 59Calibration

DECEL ...56TACHVOLTS...57Application Notes 60Multiple fixed speeds ...

Página 68 - Application Notes

62Application NotesIndependent adjustable speedsReplace the speed adjust potentiometer with a single pole,multi-position switch, and two or more poten

Página 69 - 61Application Notes

63Application NotesATTENTION: The DC3 Drive is intended to operateat a predetermined minimum speed. If the applicationrequires zero speed operation, t

Página 70 - Independent adjustable speeds

64 Application NotesFigure 17. Reversing Circuit Connection250-0287-rev2.qxd 3/12/01 10:27 AM Page 64

Página 71 - Reversing

65Application NotesRUN/JOG switchUsing a RUN/JOG switch is recommended in applicationswhere quick stopping is not needed and frequent jogging isrequir

Página 72 - 64 Application Notes

66 Application NotesFigure 18. RUN/JOG Switch Connection toSpeed Adjust Potentiometer250-0287-rev2.qxd 3/12/01 10:27 AM Page 66

Página 73 - RUN/JOG switch

67TroubleshootingBefore troubleshootingPerform the following steps before starting any procedurein this section:• Disconnect AC line voltage from the

Página 74 - Speed Adjust Potentiometer

68 TroubleshootingFigure 19. Diagnostic LED LocationsDiagnostic LEDsDC3N Series drives are equipped with two diagnosticLEDs (see Figure 19 for LED loc

Página 75 - Troubleshooting

69Problem PossibleCausesSuggestedSolutionsTroubleshootingLine fuse blows 1. Line fuses arethe wrong size.2. Motor cable orarmature is shortedto ground

Página 76 - Diagnostic LEDs

70Problem PossibleCausesSuggestedSolutionsTroubleshootingLine fuse doesnot blow, butmotor does notrun1. Speed adjustpotentiometer,voltage externalrefe

Página 77 - Solutions

71Problem PossibleCausesSuggestedSolutionsTroubleshootingLine fuse doesnot blow, butmotor does notrun (cont.)5. Drive is notreceiving AC linevoltage.6

Página 78

Figure 1. DC3N-12D-00-010-AI Dimensions ...4Figure 2. DC3N-12D-4X-010-AI Dimensions ...5Figure 3. PC Board Layout ...

Página 79

72Problem PossibleCausesSuggestedSolutionsTroubleshootingMotor runs toofast at set speed1. MIN SPD andMAX SPD settingsare too high.2. Motor fieldconne

Página 80

73Problem PossibleCausesSuggestedSolutionsTroubleshootingMotor runs tooslow or too fast1. Switches are setincorrectly.2. MIN SPD andMAX SPD notcalibra

Página 81

74Problem PossibleCausesSuggestedSolutionsTroubleshootingMotor will notreach thedesired speedMotor pulsatesor surges underload1. MAX SPDsetting is too

Página 82

75TroubleshootingFigure 20. DC3N Block DiagramBlock Diagram250-0287-rev2.qxd 3/12/01 10:27 AM Page 75

Página 83 - Block Diagram

Terminal descriptionsChassis drive terminalsL1 (TB501)Hot terminal for AC line voltage.L2/115 (TB501)Neutral terminal for 115 VAC line voltage.L2/230

Página 84 - Terminal descriptions

T1, T2 (TB502)Connections to optional external tachometer.Enclosed drive terminalsL1 (terminal 1)Hot terminal for AC line voltage.L2/115 (terminal 2)N

Página 85 - 77Troubleshooting

Reliance Electric Corporation hereby certifies that itsDC3N series drives have been approved to bear the “CE”mark provided the conditions of approval

Página 86 - CE Compliance

79CEComplianceExhibit “A”In addition to EMI/RFI safeguards inherent in the DC3Nseries’ design, external filtering is required.Reliance Electric requir

Página 87 - Exhibit “A”

80 CE ComplianceIf the end-user is using a CE-approved motor, the correctfilter from Table 5 is all that is necessary to meet the EMCdirectives listed

Página 88 - Armature Filters

The filters in Table 6 must be wired to the DC output ofthe drive, as close to the drive as possible. The groundconnection from the filter must be wir

Página 89 - 81CE Compliance

SpecificationsMax.Armature HP Range HP RangeCurrent with115 VAC with 230 VACModel (Amps DC) Applied AppliedDC3N-12D-00-010-AI 10A 1/4–1 1/2–2DC3N-12D-

Página 90

Notes250-0287-rev2.qxd 3/12/01 10:27 AM Page 82

Página 91

250-0287-rev2.qxd 3/12/01 10:27 AM Page 83

Página 92

U.S. Drives Technical Support Tel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: [email protected], Online: www.ab.com/support/abdrives