Rockwell-automation CIP Motion Popular Configuration Drawing With Note Manual do Utilizador Página 3

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 6
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 2
PowerFlex 4 Class VFD
POINT I/O
POINTGuard I/O
(Safety I/O)
Kinetix 6500 Servo Drive
Stratix 6000 Switch
Integrated Motion on EtherNet/IP: 8 Axis
Linear/Star with PowerFlex 755 and Safety
Note: Performance is what we tested,
not the max capacity
Safety Capacity
Distributed Safety
functionality across
the network supported
in such products as
CompactBlock Guard I/O,
POINT Guard I/O,
Kinetix 6500, and
PowerFlex 755
PV+
HMI
1783-ETAP
PanelView Plus
CompactBlock Guard I/O
(Safety I/O)
Camera
Plant MRP
System, Database,
Order Tracking Systems
Configuration
EtherNet/IP, DeviceNet and RA
Controllers enable business systems
to plant floor communications, providing
t
he ability to share thousands of pieces of
information with no programming required
Integrated Motion on EtherNet/IP Configuration
Mix and match Motion, Standard I/O ,
and Safety devices on one network.
Either Star, Linear, or Device Level Ring (DLR)
topologies can be used (or a mix of these topologies)
ArmorBlock
SOE I/O
Module
Capacity
ControlLogix/1756-ENXT(R)
Performance
• 8 drives/ms using either a 1756-EN2T(R)
or 1756-EN3T module
ControlLogix/1756-ENXT(R) Configuration
• USB Port on 1756-EN2T(R)/EN3TR provides easy access to
module and networks for configuration, and troubleshooting
PowerFlex 755*
Architecture
Class Drive
PowerFlex 755 VFD Configuration
Full integrated motion support for PowerFlex 755*/Kinetix 6500 using EtherNet/IP
Can configure for position, velocity, torque,or V/Hz control
RSLogix 5000 common integrated motion programming, configuration, commissioning,
and motion tools for the PowerFlex 755*/Kinetix 6500
Use same Motion instructions for Kinetix 6500/PowerFlex 755*
Safety Options:
- SIL 3, Cat 3, PLe Safe Torque Off
- SIL 3, Cat 4, PLe Safe Speed
PowerFlex 755 VFD Performance
Speed, Position, and Torque Control
PowerFlex 755 VFD Capacity
1-650Hp
.75-400kW
400/480VAC & 540/650VDC
Embedded EtherNet/IP
Integrated Motion on EtherNet/IP Allows you to Use One Network to Integrate High Performance Servo & AC Drive Control,
Distribute I/O, HMI, and other EtherNet/IP Devices, for Standard and Safety Applications
ControlLogix/1756-ENXT(R) Capacity
• 1-8 position configured drives
with 1756-EN2T(R)
1-255 position configured drives
with 1756-EN3TR (with multiple conrollers)
• Unlimited velocity, torque, and
Vhz configured drives
• Logix controller drive limit of 100 drives
POINT I/O Capacity
The maximum is 63 POINT I/O modules per adapter
1734-AENTR EtherNet/IP adapter utilizes embedded
switch technology to support linear or ring topologies
You can mix Safety and Standard Point I/O modules
in the same rack
T
he 1783-ETAP can be used to
connect devices that do not currently
have the 2 port embedded linear/ring technology.
Switch Configurations Options
Can use embeddeded, unmanaged, or managed switches
from any switch manufacturer.
Recommended Rockwell Automation switchces available include:
-Stratix 8000 and 6000 Managed Switches
-Stratix 2000 unmanaged switch
2 port embedded linear/ring technology available in:
- 1756-EN2TR ControlLogix module
- 1756-EN3TR ControlLogix module
- 1734-AENTR Point I/O Adapter
-
ArmorBlock SOE I/O module
- Kinetix 6500
1783-ETAP Standalone 3 port tap allows any single port
device to participate
Switch Performance
In many applications an external switch is not required due to
the high precision 2 port embedded linear/ring technology included
in the products
In topologies where an external switch is used (e.g. Star), either
a managed or unmanaged switch can be used, depending on your
application requirements
POWER
Power Supply
ControlLogix
RUN I/O
RS232
OK
F
ORCE
BAT
RUN REM PROG
Logix5562S
SAFETY
R
UN
SAFETY
T
ASK
OK
BAT
Logix55LSP
GuardLogix *
OK
AB
A
B
CPU
EtherNet/IP
OK
AB
1756-EN2T
* Optional Modules
• GuardLogix only required
for safety applications
Kinetix 6500 Configuration
Full integrated motion support for Kinetix 6500/ PowerFlex 755* using EtherNet/IP
Can configure for position, velocity, or torque control
RSLogix 5000 common integrated motion programming, configuration, commissioning,
and drive dignostic & maintenance tools for the Kinetix 6500/ PowerFlex 755*
Use same Motion instructions for Kinetix 6500/PowerFlex 755*
Safety Options:
- SIL 3, Cat 4, PLe Safe Torque Off
- SIL 3, Cat 4, PLe Safe Speed (dual encoder)
- SIL 2 Pld Safe Speed (single encoder)
Kinetix 6500 Performance
High speed registration input on Kinetix drive
can trigger a motion task in RSLogix 5000
for faster event task performance
Kinetix 6500 Capacity
460V AC Input Voltage
1.8 kW to 22 kW
0.18-134 Nm torque (1.59-1186 lb-in)
• Up to 7250 rpm
• Up to 2,000,000 feedback resolution
• Embedded EtherNet/IP
ArmorBlock SOE I/O Module Capacity
Sequence of Events (SOE) module
Time stamp data can be used for
motion soft registration support
Includes 100us transition time stamp
* RSLogix 5000 support for PowerFlex 755 with Integrated Motion available August 2010.
Publication IASIMP-QR019B-EN-P May 2010
Supersedes Publication IASIMP-QR019A-EN-P March 2010
IASIMP-QR019B-EN-P.qxp:Layout 1 5/4/10 11:34 AM Page 3
Vista de página 2
1 2 3 4 5 6

Comentários a estes Manuais

Sem comentários