Programming
Chapter 2
2-32
ANALOG OUTPUT Menu The ANALOG OUTPUT menu (see Figure 10.1) allows the analog output
signals to be properly configured. These selections will not become active
until the data has been stored in EEPROM by transitioning the Drive
Enable input from Off to On.
Figure 2.8
Analog Output Menu Tree
ANALOG OUTPUT
Output #1
Output #2
Output #1
This parameter allows Analog Output #1 to be configured for the desired
output parameter.
Possible Choices | MOTOR RPM | (Absolute Value)
MOTOR RPM (Bipolar Value)
| SPINDLE RPM | (Absolute Value)
SPINDLE RPM (Bipolar Value)
% LOAD
% TORQUE
POWER
ORIENT ERROR
Default Value | MOTOR RPM | (Absolute Value)
Output #2
This parameter allows Analog Output #2 to be configured for the desired
output parameter.
Possible Choices | MOTOR RPM | (Absolute Value)
MOTOR RPM (Bipolar Value)
| SPINDLE RPM | (Absolute Value)
SPINDLE RPM (Bipolar Value)
% LOAD
% TORQUE
POWER
ORIENT ERROR
Default Value % LOAD