20 Rockwell Automation Publication 6180P-UM001C-EN-P - February 2014
Chapter 2 Installation
Mounting Clearance
Requirements
Figure 6 - Minimum Clearances
IMPORTANT
Because of self-heating, do not operate the computer in an enclosure with the
minimum clearances unless adequate ventilation or other cooling methods are
used to lower the temperature within the enclosure.
Allow enough clearance to easily install or remove peripheral
components, such
as internal drives.
1
2
3
4
5
Item Description Value
1 Top 50 mm (2 in.)
2Left 50 mm (2 in.)
3Rear
Air flow
ODD
HDD access
25 mm (1 in.)
140 mm (5.5 in.)
178 mm (7 in.)
4Right
I/O port access and
ventilation
76.2 mm (3 in.)
5 Bottom 102 mm (4 in.)
Right and left are based on facing the front of the
computer.