Defining Strings for Serial Ports and Viewports
8 29
The string is sent for each index value, until the index value exceeds the
End value.
For example, to repeat a string 5 times, you can set the Start value to 1, the
End value to 5, and the Increment to 1. The index will increment through
values 1 to 5. Or, you can set the Start value to 6, the End value to 10, and
set the Increment to 1, so the index will increment from 6-10, and so forth.
You can use the # (index) character in a string; when the # is placed in the
string text, the Color CVIM module replaces the # with the current index
value when the string is transmitted or displayed (see also Example of
Using the Repeat String and Index Character in this chapter).
Setting Repeat String Parameters
To set the Repeat String parameters:
Pick the Repeat String box on the Define String menu to display the
Repeat String menu:
Repeat String menu
With the Repeat String menu displayed, you can set the Start, Increment,
and End values.
Set the Start, Increment, and End values by picking the respective box
for each; when you pick any of these items, a calculator keypad appears
which you must use to enter the respective value (see Figure 8.8).