QUICK START
ARMORSTART
®
DISTRIBUTED
MOTOR CONTROLLER WITH
ARMORPOINT
®
BACKPLANE
Getting Started
BULLETIN 284A
Introduction
This guide provides the basic information required to start up your
ArmorStart
®
Distributed Motor Controller. Factory default settings
and information regarding installing, programming, and ArmorPoint
®
Communication Protocol, are described here. For detailed
information on specific product features or configurations, refer to the
ArmorStart user manual, Publication 284-UM001*-EN-P.
This guide is intended for qualified service personnel responsible for
setting up and servicing these devices. You must have previous
experience with and a basic understanding of electrical terminology,
configuration procedures, required equipment, and safety precautions.
For Bulletin 284A devices, you should understand Bulletin 1738
ArmorPoint adapter and I/O products.
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - BACKPLANE

QUICK STARTARMORSTART® DISTRIBUTED MOTOR CONTROLLER WITH ARMORPOINT® BACKPLANEGetting StartedBULLETIN 284AIntroductionThis guide provides the basic in

Página 2

10 Publication 284A-QS001C-EN-P - July 2006Figure 7 Control Power Media System Overview➏ Control Power Media Patchcords - PatchCord cable with

Página 3 - Conduit Entrance

Publication 284A-QS001C-EN-P - July 2006 11ArmorStart with ArmorConnect ConnectivityInstalling ArmorConnect Power Media using Cord GripsContro

Página 4 - 4

12 Publication 284A-QS001C-EN-P - July 2006ArmorConnect Cable RatingsThe ArmorConnect Power Media cables are rated per UL Type TC 600V 90 °C Dr

Página 5 - ArmorConnect™ Connectivity

Publication 284A-QS001C-EN-P - July 2006 13Group Motor Installations for USA and Canada MarketsThe ArmorStart Distributed Motor controllers are

Página 6 - 6

14 Publication 284A-QS001C-EN-P - July 2006meant to be unplugged and replaced after proper lockout/tag-out procedures have been employed.Since

Página 7 - Specifications

Publication 284A-QS001C-EN-P - July 2006 15Figure 8 Removal of Control ModuleFigure 9 Jumper RemovalRemove JumperATTENTION!Do not remove this j

Página 8

16 Publication 284A-QS001C-EN-P - July 2006LED Status Indication The LED Status Indication provides 4 status LEDs and a Reset button. The LEDs

Página 9 - Description

Publication 284A-QS001C-EN-P - July 2006 17When connecting to the Bulletin 1738 ArmorPoint Distributed I/O product, a network adapter and at le

Página 10 - Enclosure

18 Publication 284A-QS001C-EN-P - July 2006Details on Using the “ArmorStart Ladder Logic Configurator”The ArmorStart Ladder Logic Configurator

Página 11 - 11

Publication 284A-QS001C-EN-P - July 2006 19Theory of OperationIt is possible to connect an ArmorStart product to the Point I/O based subnet of

Página 13 - 13

20 Publication 284A-QS001C-EN-P - July 2006I/O Tree OverviewIn order to transfer I/O information, the ArmorStart needs to be added to the I/O t

Página 14 - AC Supply Considerations

Publication 284A-QS001C-EN-P - July 2006 21Logic Configuration DetailsInside the Configurator file is a large User Defined structure called Arm

Página 15 - EMI filter installed

22 Publication 284A-QS001C-EN-P - July 2006Figure 17 Array Size Parameter Armor_Start_System.Num_Devices defaults to zero and is defined as the

Página 16 - 16

Publication 284A-QS001C-EN-P - July 2006 23Figure 18 Communication Card ConfigurationNote: To easily edit an ASCII string, click on the strin

Página 17 - 17

24 Publication 284A-QS001C-EN-P - July 2006modified. The parameter numbers all start with 1 and are numbered sequentially to the last parameter

Página 18 - 18

Publication 284A-QS001C-EN-P - July 2006 25Triggering a System Wide ReadOnce the system configuration has been done, a System Wide Read must be

Página 19 - Theory of Operation

26 Publication 284A-QS001C-EN-P - July 2006Interpreting the Error ReportIf an error occurs during the operation of the ladder logic, either the

Página 20 - I/O Tree Overview

Publication 284A-QS001C-EN-P - July 2006 27Bulletin 284 PararmetersTable 4 Basic Program Group for Sensorless Vector Performance➊ Stop drive be

Página 21 - Logic Configuration Details

28 Publication 284A-QS001C-EN-P - July 2006Table 5 Basic Program Group for Sensorless Vector Control➊ Stop drive before changing this parameter

Página 22 - 22

Publication 284A-QS001C-EN-P - July 2006 29Quick Reference TroubleshootingThere are four LEDs on the front of the ArmorStart that can provide a

Página 23 - Figure 20 String Browser Box

Publication 284A-QS001C-EN-P - July 2006 3Installation The ArmorStart Distributed Motor Controller is convection cooled. Operating temperature

Página 24 - Figure 21 Data Array

30 Publication 284A-QS001C-EN-P - July 2006Fault LED Indications for Bulletin 284A ArmorStart Distributed Motor ControllersTable 8 Controller F

Página 25 - Triggering a System Wide Read

Publication 284A-QS001C-EN-P - July 2006 31Internal Drive FaultsA fault is a condition that stops the drive. There are two fault types.Table 9

Página 26 - Interpreting the Error Report

32 Publication 284A-QS001C-EN-P - July 2006Table 10 Fault Types, Descriptions, and Actions➊ See Table 9 for internal drive fault types.No. Faul

Página 27 - Bulletin 284 Pararmeters

Publication 284A-QS001C-EN-P - July 2006 33Table 10 Fault Types, Descriptions, and Actions (Continued)➊ See Table 9 for internal drive fault

Página 28 - IMPORTANT

34 Publication 284A-QS001C-EN-P - July 2006Accessories Table 11 DeviceNet Media ➊➊See publication M116-CA001A-EN-P for complete cable selection

Página 29 - Troubleshooting

Publication 284A-QS001C-EN-P - July 2006 35Table 13 Sensor Media ➊ ➊See Publication M116-CA001A-EN-P for complete cable selection information.➋

Página 30 - Distributed Motor Controllers

36 Publication 284A-QS001C-EN-P - July 2006Bulletin 1738 ArmorPoint Distributed I/O ProductsTable 15 Digital I/O ProductsTable 16 Digital Input

Página 31 - Internal Drive Faults

Publication 284A-QS001C-EN-P - July 2006 37Table 18 Power Supply ProductsTable 19 AC and Relay ProductsTable 20 Specialty ProductsDescription C

Página 32

38 Publication 284A-QS001C-EN-P - July 2006Table 21 Adapter ProductsDescription Cat. No.0ArmorPoint DeviceNet Adapter Module, Drop or Pass-thro

Página 34 - Table 12 ArmorPoint Media

4 Publication 284A-QS001C-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Página 35 - Table 14 Sealing Caps

Publication 284A-QS001C-EN-P — July 2006 41053-384-04Superecedes Publication 284A-QS001B-EN-P — September 2005 Copyright ©2006 Rockwell Automation, In

Página 36 - Table 17 Analog Products

Publication 284A-QS001C-EN-P - July 2006 5Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Página 37 - Table 20 Specialty Products

6 Publication 284A-QS001C-EN-P - July 2006Dimensions are shown in millimeters (inches). Dimensions are not intended to be used for manufacturin

Página 38 - Table 21 Adapter Products

Publication 284A-QS001C-EN-P - July 2006 7Wiring Power, Control, Safety Monitor Inputs, and Ground Wiring Table 1 provides the power, control,

Página 39

8 Publication 284A-QS001C-EN-P - July 2006Table 2 Power, Control, and Ground Terminal Designations➊ Only available with the Safety Monitor opti

Página 40 - Trademark List

Publication 284A-QS001C-EN-P - July 2006 9ArmorConnect Power Media DescriptionThe ArmorStart Power Media offers both three-phase and control po

Comentários a estes Manuais

Sem comentários