4–18 Creating the Sample Application
Publication 2711-6.2
To create the MODE indicator:
Mode indicator
1. From the Objects
"
Indicators submenu choose Multistate.
2. Position the pointer (+) in the lower left area of the box, hold
down the left mouse button and drag the pointer to size the
indicator.
3. Click the right mouse button to exit multistate indicator mode.
4. Choose None from the Format
"
Line Type submenu.
Or click
on the Format bar and choose None.
To set the properties of the MODE indicator:
1. Double-click the indicator object to open its dialog.
2. Set the properties as shown below.
Click Value
Type Motor AutoMan_Ind (for Remote I/O)
or Motor_AutoManual (for DH-485)
Creating the
Motor Status Screen