Rockwell-automation 20B PowerFlex 700 Custom Firmware - Option AX Manual do Utilizador Página 2

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 2
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 1
2 PowerFlex® 700 VC Custom Firmware
Table A Modified Parameters:
Parameter “AX” Option PowerFlex 700 VC Standard
55 – Maximum Freq Min = 5.0 Hz
Max = 82.0 Hz
Default = 82.0 Hz
Min = 5.0 Hz
Max = 420.0 Hz
Default = 130.0 Hz
82 – Maximum Speed Min = 5.0 Hz
Max = 80.0 Hz
Default = 80.0 Hz
Min = 5.0 Hz
Max = 420.0 Hz
Default = 60.0 Hz
83 – Overspeed Limit Min = 0.0 Hz
Max = 2.0 Hz
Default = 2.0 Hz
Min = 0.0 Hz
Max = 20.0 Hz
Default = 10.0 Hz