Resumo do Conteúdo

Página 1 - User Manual

PowerFlex 20-750-ENETR Dual-port EtherNet/IP Option ModuleFirmware Revision Number 1.xxxUser Manual

Página 2 - Important User Information

10 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 1 Getting Started FeaturesThe features of the option module include the fol

Página 3 - Table of Contents

100 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) Table 5 - Explicit Messagi

Página 4

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 101Using Explicit Messaging (Adapter mode only) Chapter 6 For information on the maxi

Página 5

102 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) ControlLogix – Formatting a

Página 6

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 103Using Explicit Messaging (Adapter mode only) Chapter 6 ControlLogix Controller Exa

Página 7 - Rockwell Automation

104 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) ControlLogix – Formatting a

Página 8 - Additional Resources

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 105Using Explicit Messaging (Adapter mode only) Chapter 6 ControlLogix Controller Exa

Página 9 - Getting Started

106 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) ControlLogix – Formatting a

Página 10 - Features

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 107Using Explicit Messaging (Adapter mode only) Chapter 6 ControlLogix Controller Exa

Página 11 - Option Module Operating

108 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) ControlLogix Controller Exa

Página 12 - Understanding Parameter

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 109Using Explicit Messaging (Adapter mode only) Chapter 6 ControlLogix – Formatting a

Página 13 - Required Equipment

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 11Getting Started Chapter 1 • Master-Slave or Peer-to-Peer hierarchy that can be conf

Página 14 - Safety Precautions

110 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) ControlLogix Controller Exa

Página 15 - Quick Start

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 111Using Explicit Messaging (Adapter mode only) Chapter 6 ControlLogix Controller – E

Página 16

112 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 6 Using Explicit Messaging (Adapter mode only) When performing a Scattered

Página 17 - Installing the Option Module

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 113 Chapter 7TroubleshootingThis chapter provides information for diagnosing and trou

Página 18

114 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 7 Troubleshooting Indications for Adapter Mode OperationUse the following

Página 19 - Setting the Operating Mode

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 115Troubleshooting Chapter 7 NET A Status Indicator—Adapter ModeThis red/green bicolo

Página 20 - Setting the Node Address

116 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 7 Troubleshooting Indications for Tap Mode OperationUse the following sect

Página 21

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 117Troubleshooting Chapter 7 LINK 2 Status Indicator—Tap ModeThis green/yellow bicolo

Página 22 - Module to the Drive

118 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 7 Troubleshooting Viewing Option Module Diagnostic ItemsIf you encounter u

Página 23 - Module to the Network

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 119Troubleshooting Chapter 7 27 DL To Net 01 Val The present value of respective Host

Página 24 - ENET2 network ports are used

12 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 1 Getting Started used in a linear or device-level ring (DLR) network topol

Página 25

120 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 7 Troubleshooting 59606162Subnet Act 1Subnet Act 2Subnet Act 3Subnet Act 4

Página 26 - Start-Up Status Indications

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 121Troubleshooting Chapter 7 Diagnostic Items for Tap Mode OperationTable 11 - Tap Mo

Página 27 - and page 115

122 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 7 Troubleshooting Viewing and Clearing EventsThe option module has an even

Página 28 - or page 116

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 123Troubleshooting Chapter 7 Table 12 - Option Module EventsCode Event Text Descript

Página 29

124 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 7 Troubleshooting 37 Net IO Timeout An I/O connection from the network to

Página 30 - Commissioning the Option

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 125 Chapter 8Viewing Option Module Web PagesThis chapter provides instructions on how

Página 31 - Configuring the Option Module

126 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 8 Viewing Option Module Web Pages The computer can access option module we

Página 32 - Node Address

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 127Viewing Option Module Web Pages Chapter 8 Navigation Pane on Adapter Mode Web Page

Página 33 - 1<<3

128 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 8 Viewing Option Module Web Pages Adapter Mode Process Display Pop-up Dial

Página 34

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 129Viewing Option Module Web Pages Chapter 8 Adapter Mode TCP/IP Configuration Web Pa

Página 35

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 13Getting Started Chapter 1 Compatible ProductsAt the time of publication, the option

Página 36 - Setting the IP Address

130 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 8 Viewing Option Module Web Pages Adapter Mode Configure E-mail Notificati

Página 37 - Setting the Gateway Address

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 131Viewing Option Module Web Pages Chapter 8 3. Type the following information in the

Página 38 - 0<<4

132 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 8 Viewing Option Module Web Pages Figure 43 shows an example e-mail messag

Página 39 - (Adapter mode only)

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 133Viewing Option Module Web Pages Chapter 8 Adapter Mode Device Information PagesAda

Página 40

134 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 8 Viewing Option Module Web Pages Figure 45 - Example of Adapter Mode Port

Página 41 - Simple Peer I/O Configuration

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 135Viewing Option Module Web Pages Chapter 8 Figure 48 shows an example event queue p

Página 42 - 0<<2

136 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 8 Viewing Option Module Web Pages Viewing Web Pages in Tap ModeIn Tap mode

Página 43

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 137 Appendix ASpecificationsThis appendix presents the specifications for the option

Página 44 - 10.00 Secs

138 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix A Specifications When Operating in Tap ModeElectricalMechanicalEnvironmen

Página 45

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 139 Appendix BOption Module ParametersThis appendix provides information about the op

Página 46 - Changing the Fault Action

14 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 1 Getting Started Safety PrecautionsPlease read the following safety precau

Página 47

140 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters About Parameter NumbersEach parameter set is i

Página 48 - Disabled 0

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 141Option Module Parameters Appendix B 07080910[IP Addr Cfg 1][IP Addr Cfg 2][IP Addr

Página 49 - Resetting the Option Module

142 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters 20 [Net Rate Act 1]Displays the actual speed a

Página 50 - Rev 3.002 Ser. A

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 143Option Module Parameters Appendix B 28 [DLs Fr Peer Cfg]Sets the number of peer-to

Página 51 - Status Using Parameters

144 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters 32 [Fr Peer Timeout]Sets the timeout for a pee

Página 52 - Firmware

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 145Option Module Parameters Appendix B 39 [DLs To Peer Cfg]Sets the number of drive-t

Página 53 - Configuring the I/O

146 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters Host Parameters—Adapter ModeParameterNo. Name

Página 54 - Example (Adapter mode

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 147Option Module Parameters Appendix B 33 [Comm Flt Action]Sets the action that the o

Página 55

148 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters 35 [Peer Flt Action]Sets the action that the o

Página 56 - Box Setting

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 149Option Module Parameters Appendix B 38 [Flt Cfg Ref]Sets the Reference data that i

Página 57

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 15Getting Started Chapter 1 Quick StartThis section is provided to help experienced u

Página 58

150 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters Parameters for Tap Mode OperationThis section

Página 59

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 151Option Module Parameters Appendix B 11121314[Subnet Cfg 1][Subnet Cfg 2][Subnet Cf

Página 60

152 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix B Option Module Parameters Host Parameters—Tap ModeWhen operating the opt

Página 61 - Configuring the I/O Chapter 4

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 153 Appendix CEtherNet/IP Objects (Adapter mode only)This appendix presents informati

Página 62

154 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Identity ObjectClass Code Serv

Página 63

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 155EtherNet/IP Objects (Adapter mode only) Appendix C Assembly ObjectClass Code Serv

Página 64

156 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Register ObjectClass Code Serv

Página 65

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 157EtherNet/IP Objects (Adapter mode only) Appendix C PCCC ObjectClass Code Services

Página 66

158 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Message Structure for Execute_D

Página 67

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 159EtherNet/IP Objects (Adapter mode only) Appendix C N-Files N-File DescriptionN42

Página 68

16 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 1 Getting Started Tap Mode of Operation (only with PowerFlex 755 drives) S

Página 69

160 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) DPI Device Object Class Code S

Página 70

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 161EtherNet/IP Objects (Adapter mode only) Appendix C Class Attributes Attribute ID

Página 71

162 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Instance Attributes 20 Set Cus

Página 72

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 163EtherNet/IP Objects (Adapter mode only) Appendix C DPI Parameter ObjectClass Code

Página 73

164 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Instance Attributes Attribute

Página 74 - ADC and Logix Memory

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 165EtherNet/IP Objects (Adapter mode only) Appendix C 16 Get Parameter Processing Err

Página 75

166 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Descriptor Attributes Bit Name

Página 76

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 167EtherNet/IP Objects (Adapter mode only) Appendix C Extended Descriptor Attributes

Página 77

168 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Formulas for ConvertingDisplay

Página 78

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 169EtherNet/IP Objects (Adapter mode only) Appendix C DPI Fault ObjectClass Code Pro

Página 79 - Monitoring ADC Progress

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 17 Chapter 2Installing the Option ModuleThis chapter provides instructions for instal

Página 80

170 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Class Attributes Instance Attr

Página 81

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 171EtherNet/IP Objects (Adapter mode only) Appendix C DPI Alarm ObjectClass Code Pro

Página 82

172 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Instance Attributes Attribute

Página 83

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 173EtherNet/IP Objects (Adapter mode only) Appendix C DPI Diagnostic ObjectClass Code

Página 84

174 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Instance Attributes Attribute

Página 85

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 175EtherNet/IP Objects (Adapter mode only) Appendix C DPI Time ObjectClass Code Serv

Página 86

176 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Instance Attributes 8 Get Acti

Página 87 - About I/O Messaging

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 177EtherNet/IP Objects (Adapter mode only) Appendix C Host DPI Parameter ObjectClass

Página 88 - Understanding the I/O Image

178 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Instance Attributes Attribute

Página 89 - Using Reference/Feedback

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 179EtherNet/IP Objects (Adapter mode only) Appendix C 16 Get Parameter Processing Err

Página 90 - Using Datalinks

18 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module Much of EtherNet/IP implicit (I/O) messaging

Página 91 - Program Information

180 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Descriptor Attributes Bit Name

Página 92

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 181EtherNet/IP Objects (Adapter mode only) Appendix C Extended Descriptor Attributes

Página 93

182 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) Formulas for ConvertingDisplay

Página 94 - Versions

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 183EtherNet/IP Objects (Adapter mode only) Appendix C TCP/IP Interface ObjectClass Co

Página 95 - Program

184 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) 2 Get Configuration Capability

Página 96 - Program Tags

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 185EtherNet/IP Objects (Adapter mode only) Appendix C Ethernet Link ObjectClass Code

Página 97 - Example Datalink Data

186 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix C EtherNet/IP Objects (Adapter mode only) 5 Get Media Counters STRUCT of:

Página 98 - Generic Profile

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 187 Appendix DLogic Command/Status Words: PowerFlex 750-Series DrivesThis appendix pr

Página 99 - About Explicit Messaging

188 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Appendix D Logic Command/Status Words: PowerFlex 750-Series Drives Logic Status Wo

Página 100

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 189 GlossaryThe following terms and abbreviations are used throughout this manual. Fo

Página 101 - Examples

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 19Installing the Option Module Chapter 2 Setting the Operating ModeThe option module

Página 102

190 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Glossary Device-level Ring (DLR) An Ethernet topology that consist of multiple dev

Página 103 - Single Parameter

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 191Glossary Explicit Messaging Explicit messages are used to transfer data that does

Página 104

192 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Glossary IP Addresses A unique IP address identifies each node on an EtherNet/IP n

Página 105 - Multiple Parameters

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 193Glossary NVS (Nonvolatile Storage) NVS is the permanent memory of a device. Device

Página 106

194 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Glossary Status Indicators Status indicators are LEDs that are used to report the

Página 107

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 195 IndexAADC (Automatic Device Configuration) 67, 189applying power to the option mo

Página 108

196 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Index explicit messagingabout 99configuring for ControlLogix controller 101definit

Página 109

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 197Index NNET A status indicator (Adapter mode)locating 113troubleshooting with 115Ne

Página 110

198 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Index PowerFlex 750-Series (Architecture Class) drivescompatible with option modul

Página 112 - Request (Source Data) array

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guideli

Página 113 - Troubleshooting

20 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module Setting the Node AddressThere are four metho

Página 114 - Operation

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Publication 750COM-UM008A-EN-P - J

Página 115

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 21Installing the Option Module Chapter 2 • DHCP (Dynamic Host Configuration Protocol

Página 116 - Indications for Tap Mode

22 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module The Node Address switch settings can be veri

Página 117

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 23Installing the Option Module Chapter 2 Connecting the Option Module to the NetworkT

Página 118 - Diagnostic Items

24 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module Figure 4 - Connecting the Ethernet Cable in

Página 119

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 25Installing the Option Module Chapter 2 When Operating in Tap Mode (only PowerFlex 7

Página 120

26 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module Applying PowerApply power to the drive. The

Página 121

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 27Installing the Option Module Chapter 2 Table 1 - Adapter Mode – Drive and Option Mo

Página 122 - Viewing and Clearing Events

28 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module Table 2 - Tap Mode – PowerFlex 755 Drive and

Página 123

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 29Installing the Option Module Chapter 2 Configuring and Verifying Key Drive Paramete

Página 124

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 3 Table of ContentsPrefaceConventions Used in This Manual . . . . . . . . . . . . .

Página 125 - Adapter Mode

30 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 2 Installing the Option Module problem occurs, this verification step provi

Página 126

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 31 Chapter 3Configuring the Option ModuleThis chapter provides instructions and infor

Página 127

32 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Using the PowerFlex 20-HIM-A6 or 20-HIM-C6S

Página 128 - Display Pop-up Dialog Box

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 33Configuring the Option Module Chapter 3 1. Depending on the type of server (BOOTP o

Página 129 - Configuration Web Page

34 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module The BOOTP/DHCP Server dialog box appears.

Página 130 - Adapter Mode Configure E

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 35Configuring the Option Module Chapter 3 7. In the BOOTP/DHCP Request History list,

Página 131

36 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Using Option Module ParametersBy default, t

Página 132

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 37Configuring the Option Module Chapter 3 Setting the Subnet Mask1. Verif y that Devi

Página 133 - Information Pages

38 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Setting the Data RateBy default, the option

Página 134

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 39Configuring the Option Module Chapter 3 Selecting Master-Slave or Peer-to-Peer Hier

Página 135

4 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Table of Contents Chapter 5Using the I/O (Adapter mode only)About I/O Messaging . .

Página 136 - Viewing Web Pages in Tap

40 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Using the formula, the value for Host Param

Página 137 - Specifications

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 41Configuring the Option Module Chapter 3 When using a ControlLogix controller and th

Página 138 - Regulatory Compliance

42 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module 1. Set Device Parameters 41 - [To Peer Peri

Página 139 - Option Module Parameters

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 43Configuring the Option Module Chapter 3 1. Decide how many Datalink parameters you

Página 140 - Mode Operation

44 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module 4. Set Device Parameter 32 - [Fr Peer Timeo

Página 141

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 45Configuring the Option Module Chapter 3 7. If a Logic Command is being sent, use De

Página 142

46 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Setting a Fault Action (Adapter mode only)B

Página 143

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 47Configuring the Option Module Chapter 3 Changes to these parameters take effect imm

Página 144

48 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Setting Web Page AccessBy using a web brows

Página 145

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 49Configuring the Option Module Chapter 3 Resetting the Option ModuleChanges to switc

Página 146 - Host Parameters—Adapter Mode

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 5Table of Contents Appendix CEtherNet/IP Objects (Adapter mode only)Supported Data Ty

Página 147

50 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Restoring Option Module Parameters to Facto

Página 148

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 51Configuring the Option Module Chapter 3 press the ESC soft key to cancel. 9. Reset

Página 149

52 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 3 Configuring the Option Module Updating the Option Module FirmwareThe opti

Página 150 - Parameters for Tap Mode

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 53 Chapter 4Configuring the I/OThis chapter provides instructions on how to configure

Página 151

54 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O The Configure Drivers dialog box reappears with the n

Página 152 - Host Parameters—Tap Mode

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 55Configuring the I/O Chapter 4 Figure 10 - Example ControlLogix Controller EtherNet/

Página 153 - Supported Data Types

56 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O The Select Module dialog box appears.4. Expand the Co

Página 154 - Identity Object

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 57Configuring the I/O Chapter 4 10. Click OK.The bridge is now configured for the Eth

Página 155 - Assembly Object

58 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O • Unicast connection (RSLogix 5000 software, version

Página 156 - Register Object

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 59Configuring the I/O Chapter 4 The drive’s New Module dialog box appears. 4. On the

Página 157 - PCCC Object

6 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Table of Contents Notes:

Página 158

60 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 6. In the Module Definition dialog box, edit the foll

Página 159 - N-Files

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 61Configuring the I/O Chapter 4 parameters. The procedure to configure the Datalinks

Página 160 - DPI Device Object

62 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 8. Click the Connection tab. 9. In the “Requested Pa

Página 161 - Class Attributes

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 63Configuring the I/O Chapter 4 12. Click Set to save the Port Configuration informat

Página 162 - Instance Attributes

64 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O Figure 12 - Controller Output Tags Saving the I/O Co

Página 163 - DPI Parameter Object

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 65Configuring the I/O Chapter 4 2. Click Download to download the configuration to th

Página 164

66 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 2. Click the Drive tab. 3. Click Connect to Drive to

Página 165 - Extended DPI descriptor

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 67Configuring the I/O Chapter 4 6. To match the Datalinks in the drive to the project

Página 166 - Descriptor Attributes

68 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O process and saves the user time. It is particularly b

Página 167

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 69Configuring the I/O Chapter 4 Version 4.02 (or later) Drive Add-on Profiles (AOPs)V

Página 168 - Object Specific Services

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 7 PrefaceThis manual provides information about the 20-750-ENETR Dual-port EtherNet/I

Página 169 - DPI Fault Object

70 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 1. Open the drive General tab dialog box. 2. Click C

Página 170

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 71Configuring the I/O Chapter 4 Keying for peripherals is managed via the respective

Página 171 - DPI Alarm Object

72 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 6. Click the Port Properties icon to open the Prope

Página 172

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 73Configuring the I/O Chapter 4 11. Click the ADC icon to open the ADC Settings dia

Página 173 - DPI Diagnostic Object

74 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 14. Save your RSLogix 5000 project and download the p

Página 174

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 75Configuring the I/O Chapter 4 Storing the Drive’s and Peripherals’ Firmware in the

Página 175 - DPI Time Object

76 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O The Nonvolatile Memory Load/Store dialog box appears.

Página 176

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 77Configuring the I/O Chapter 4 5. Click Enabled to enable DeviceLogix after ADC. If

Página 177 - Host DPI Parameter Object

78 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O Module to allow either locking via parameter 5 or pas

Página 178

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 79Configuring the I/O Chapter 4 A configuration signature is generated.2. Access Safe

Página 179

8 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Preface Additional ResourcesThese documents contain additional information concernin

Página 180

80 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O Additional information may also be displayed on the H

Página 181

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 81Configuring the I/O Chapter 4 • A project must maintain specific revision level con

Página 182

82 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O 5. Edit the following information about the drive and

Página 183 - TCP/IP Interface Object

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 83Configuring the I/O Chapter 4 For the example in this manual, all 16 Host [DL From

Página 184

84 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O Figure 13 - Input Image Controller Tags Figure 14 -

Página 185 - Ethernet Link Object

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 85Configuring the I/O Chapter 4 The Download dialog box appears. 2. Click Download t

Página 186

86 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 4 Configuring the I/O Notes:

Página 187 - 750-Series Drives

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 87 Chapter 5Using the I/O (Adapter mode only)This chapter provides information and ex

Página 188 - Logic Status Word

88 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 5 Using the I/O (Adapter mode only) Understanding the I/O ImageThe terms in

Página 189 - Glossary

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 89Using the I/O (Adapter mode only) Chapter 5 Using Logic Command/StatusThe Logic Com

Página 190

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 9 Chapter 1Getting StartedThe 20-750-ENETR Option Module is intended for installation

Página 191

90 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 5 Using the I/O (Adapter mode only) When Parameter 300 - [Speed Units] is s

Página 192

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 91Using the I/O (Adapter mode only) Chapter 5 could change the makeup of the I/O conn

Página 193

92 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 5 Using the I/O (Adapter mode only) ControlLogix Controller ExampleThis sec

Página 194

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 93Using the I/O (Adapter mode only) Chapter 5 Figure 16 - ControlLogix Controller Exa

Página 195

94 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 5 Using the I/O (Adapter mode only) Creating Ladder Logic Using the RSLogix

Página 196

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 95Using the I/O (Adapter mode only) Chapter 5 Controller TagsWhen you add the option

Página 197

96 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 5 Using the I/O (Adapter mode only) Program TagsTo use the Controller tags

Página 198

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 97Using the I/O (Adapter mode only) Chapter 5 Figure 21 - ControlLogix Controller Exa

Página 199

98 Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012Chapter 5 Using the I/O (Adapter mode only) Figure 22 - ControlLogix Controller Exa

Página 200 - Documentation Feedback

Rockwell Automation Publication 750COM-UM008A-EN-P - July 2012 99 Chapter 6Using Explicit Messaging (Adapter mode only)This chapter provides informa