Rockwell-automation 198x Modular DeviceNet Starter Auxiliary I/O Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 198x Modular DeviceNet Starter Auxiliary I/O. Rockwell Automation 198x Modular DeviceNet Starter Auxiliary I/O User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - (Modular DSA I/O)

Modular DeviceNet Starter Auxiliary I/O(Modular DSA I/O)Bulletin 198User Manual

Página 2 - Important User Information

Publication 198-UM001B-EN-P September 2001Chapter 1Product OverviewChapter ObjectivesThis chapter contains the following information:• System descrip

Página 3 - EMC Directive

5-34 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.23 198-OW2S-Q5 Electrical and Application SchematicTable 5.X 198-OW2S-Q

Página 4 - Low Voltage Directive

Specifications 5-35Publication 198-UM001B-EN-P September 2001198-IA2XOW1 Series A and B (AC Starter Module)Figure 5.24 198-IA2XOW1 Series A an

Página 5 - Intended Audience

5-36 Specifications Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 a

Página 6 - Reference Manuals

Specifications 5-37Publication 198-UM001B-EN-P September 2001Figure 5.26 Cat. No. 198-IA2XOW1 Typical DOL wiring for Series B, Series A AC Sta

Página 7 - Chapter 3 —Operation

5-38 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.27 Typical Reversing Wiring for Series B, Hand-Off-Auto Wiring for Seri

Página 8 - Chapter 6 — Troubleshooting

Specifications 5-39Publication 198-UM001B-EN-P September 2001Figure 5.28 Replacing Cat. No. 198-IA2XOW1 Series A module with Series BATTENTION

Página 9

5-40 Specifications Publication 198-UM001B-EN-P September 2001Table 5.Z Cat. No. 198-IA2XOW1 SpecificationsTerminal Block (5.08 mm Pitch 4-Pos

Página 10 - Product Overview

Specifications 5-41Publication 198-UM001B-EN-P September 2001198-IB2XOB1 Series A and B (DC Starter Module)Figure 5.29 Cat. No. 198-IB2XOB1 Se

Página 11 - ,%6

5-42 Specifications Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 a

Página 12 - '1

Specifications 5-43Publication 198-UM001B-EN-P September 2001Figure 5.31 Cat. No. 198-IB2XOB1 Typical DOL Wiring (Series B), DC Starter Module

Página 13 - 198 – IB2XOB2S-Q5

Product Overview 1-2Publication 198-UM001B-EN-P September 2001Figure 1.1 Typical Distributed Starter — Modular-DSA I/O System Modules Mounted

Página 14 - Installation

5-44 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.32 Cat. No. 198-IB2XOB1 Typical Reversing Wiring (Series B), Hand-Off-A

Página 15 - Remove Power

Specifications 5-45Publication 198-UM001B-EN-P September 2001Figure 5.33 Replacing Cat. No. 198-IB2XOB1 Series A Module with Series B ModuleAT

Página 16 - Approximate Dimensions

5-46 Specifications Publication 198-UM001B-EN-P September 2001Table 5.AB 198-IB2XOB1 SpecificationsTerminal Block (5.08 mm Pitch 4-Position)Co

Página 17 - DIN Rail Mounting

Specifications 5-47Publication 198-UM001B-EN-P September 2001EnvironmentalAmbient Temperature Operating –25…+60°C (–4…+140°F)Storage –40…+85°C

Página 18 - Gland Plate Mounting

5-48 Specifications Publication 198-UM001B-EN-P September 2001198-IB2XOW1 Series A and B (DC Input Relay Output Module)Figure 5.34 Cat. No. 19

Página 19 - 1492-SM8X9

Specifications 5-49Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 an

Página 20 - Wiring Diagrams

5-50 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.36 Cat. No. 198-IB2XOW1Typical DOL and Reversing Wiring (Series B)A2A11

Página 21 - Operation

Specifications 5-51Publication 198-UM001B-EN-P September 2001Figure 5.37 Cat. No. 198-IB2XOW1 DC Input Relay Output Series A Module Wired to 1

Página 22

5-52 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.38 Replacing Cat. No. 198-IB2XOW1 Series A module with Series B moduleA

Página 23

Specifications 5-53Publication 198-UM001B-EN-P September 2001Table 5.AD 198-IB2XOW1 SpecificationsTerminal Block (5.08 mm Pitch 4-Position)Con

Página 24

1-3 Product Overview Publication 198-UM001B-EN-P September 2001Figure 1.3 Modular-DSA I/O System Mounted on DIN RailThe Modular-DSA I/O System

Página 25

5-54 Specifications Publication 198-UM001B-EN-P September 2001EnvironmentalAmbient Temperature Operating –25…+60°C (–4…+140°F)Storage –40…+85°

Página 26

Specifications 5-55Publication 198-UM001B-EN-P September 2001198-IB2XOB5S Series A (Drive Preset Speed Module)Figure 5.39 198-IB2XOB5S Series

Página 27

5-56 Specifications Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 a

Página 28 - Address 63 Shown

Specifications 5-57Publication 198-UM001B-EN-P September 2001Figure 5.40 198-IB2XOB5S Electrical and Application SchematicSpeed1Speed2ForwardR

Página 29 - Autobaud

5-58 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.40 198-IB2XOB5S Electrical and Application Schematic (Continued)Note: R

Página 30

Specifications 5-59Publication 198-UM001B-EN-P September 2001Figure 5.40 198-IB2XOB5S Electrical and Application Schematic (Continued)Note: Re

Página 31 - Mapping to the Scanner

5-60 Specifications Publication 198-UM001B-EN-P September 2001Table 5.AF 198-IB2XOB5S SpecificationsTerminal Block (2.54 mm Pitch 10-Position)

Página 32

Specifications 5-61Publication 198-UM001B-EN-P September 2001198-IB2XOB2S-Q5 Series A (Drive Preset Speed Module)Figure 5.41 198-IB2XOB2S-Q5 S

Página 33

5-62 Specifications Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 a

Página 34 - Advanced Topics

Specifications 5-63Publication 198-UM001B-EN-P September 2001Figure 5.42 198-IB2XOB2S-Q5 Electrical and Application Schematic2354/20 mAForward

Página 35

Product Overview 1-4Publication 198-UM001B-EN-P September 2001Cat. Nos.The catalog numbering scheme for the Modular-DSA I/O System is explaine

Página 36

5-64 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.42 198-IB2XOB2S-Q5 Electrical and Application Schematic (Continued)Auto

Página 37 - 3-17

Specifications 5-65Publication 198-UM001B-EN-P September 2001Figure 5.42 198-IB2XOB2S-Q5 Electrical and Application Schematic (Continued)Commo

Página 38

5-66 Specifications Publication 198-UM001B-EN-P September 2001Table 5.AH 198-IB2XOB2S-Q5 SpecificationsTerminal Block (2.54 mm Pitch 10-Positi

Página 39 - COS Mask Parameter

Specifications 5-67Publication 198-UM001B-EN-P September 2001198-G1P (Gland Plates)Gland plates may also be referred to as cable plates. These

Página 40

5-68 Specifications Publication 198-UM001B-EN-P September 2001Table 5.AI Gland Plate SpecificationsEnvironmentalAmbient Temperature Operating

Página 41

Specifications 5-69Publication 198-UM001B-EN-P September 2001Figure 5.45 Gland Plate Cutout SpecificationsTable 5.AJ Gland Plate Cutout Specif

Página 42 - Table 3.D Instance Table

5-70 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.46 Custom Gland Plate Drill Pattern and Ground TargetsFigure 5.47 MDSA

Página 43 - Table 3.E Blank Table

Publication 198-UM001B-EN-P September 2001Chapter 6TroubleshootingChapter ObjectivesThe purpose of this chapter is to help troubleshoot the Modular-D

Página 44

6-2 Troubleshooting Publication 198-UM001B-EN-P September 2001The MDSA system constantly checks the validity of the module combination that it

Página 45

Troubleshooting 6-3Publication 198-UM001B-EN-P September 2001many products fail to function properly, and can begin to corrupt other messages

Página 46 - DeviceNet Explicit Messaging

Publication 198-UM001B-EN-P September 2001Chapter 2InstallationChapter ObjectivesThis chapter contains information about:• Device storage and operati

Página 47 - DeviceNet I/O Messaging

6-4 Troubleshooting Publication 198-UM001B-EN-P September 2001I/O Module Current ErrorsThe MDSA system is designed to connect a large number o

Página 48 - Table 3.F I/O Module Data

Publication 198-UM001B-EN-P September 2001Appendix ADeviceNet InformationDeviceNet Module IntroductionThe 198-DN and 198-DNG DeviceNet Modules suppor

Página 49 - X = Reserved

A-2 DeviceNet Information Publication 198-UM001B-EN-P September 2001DeviceNet ImplementationThe DeviceNet Implementation in the cat. no. 198-D

Página 50 - 3-30

DeviceNet Information A-3Publication 198-UM001B-EN-P September 20015. Performs power-up initialization. If the initialization fails, the 198-D

Página 51 - Mod/Net Status LED

A-4 DeviceNet Information Publication 198-UM001B-EN-P September 2001I/O Error ModeIn I/O Error Mode, the status of all the outputs will be set

Página 52 - I/O Status LED

DeviceNet Information A-5Publication 198-UM001B-EN-P September 2001The following instance attributes are supported:The following common servic

Página 53 - Table 3.L I/O Status LED

A-6 DeviceNet Information Publication 198-UM001B-EN-P September 2001DeviceNet Object — Class ID (03hex)The following class attributes are supp

Página 54 - Programming

DeviceNet Information A-7Publication 198-UM001B-EN-P September 2001The following services are implemented for the DeviceNet Object:Assembly Ob

Página 55

A-8 DeviceNet Information Publication 198-UM001B-EN-P September 2001Each module contributes a varying amount of information to the assemblies.

Página 56

DeviceNet Information A-9Publication 198-UM001B-EN-P September 2001A description of each of the assemblies follows. All examples will use the

Página 57 - Verifying the Input Assembly

Installation 2-2Publication 198-UM001B-EN-P September 2001Electrostatic DischargeRemove PowerIMPORTANTElectrostatic discharge can damage integ

Página 58

A-10 DeviceNet Information Publication 198-UM001B-EN-P September 2001Output Assembly Instance 100This assembly reserves 4 bits (a nibble) for

Página 59 - Verifying the Output Assembly

DeviceNet Information A-11Publication 198-UM001B-EN-P September 2001Output Assembly Instance 104This output assembly reserves a byte for every

Página 60

A-12 DeviceNet Information Publication 198-UM001B-EN-P September 2001Input Assembly Instance 103This assembly reserves a byte (8 bits) for eve

Página 61 - Programming Explicit Messages

DeviceNet Information A-13Publication 198-UM001B-EN-P September 2001Input Assembly Instance 105This assembly reserves a byte (8 bits) for ever

Página 62

A-14 DeviceNet Information Publication 198-UM001B-EN-P September 2001Input Assembly Instance 107This assembly reserves a byte (8 bits) for eve

Página 63 - Programming 4-10

DeviceNet Information A-15Publication 198-UM001B-EN-P September 2001I/O Module StatusThis bit turns on when the voltage is below 18V DC. This

Página 64

A-16 DeviceNet Information Publication 198-UM001B-EN-P September 2001Error CodeThe following table describes the error codes.Connection Object

Página 65

DeviceNet Information A-17Publication 198-UM001B-EN-P September 2001Discrete Input Point Object — Class ID (08hex)Multiple instances of the Di

Página 66

A-18 DeviceNet Information Publication 198-UM001B-EN-P September 2001Multiple instances of the Discrete Output Object will be supported. All i

Página 67 - Specifications

DeviceNet Information A-19Publication 198-UM001B-EN-P September 2001Multiple instances of the Presence Sensing Object are supported. All insta

Página 68 - Table 5.A Mod/Net Status LED

2-3 Installation Publication 198-UM001B-EN-P September 2001Approximate DimensionsDimensions are in millimeters (inches).Figure 2.1 DIN Module

Página 69

A-20 DeviceNet Information Publication 198-UM001B-EN-P September 2001DeviceNet Interface Object — Class ID (B4hex)A single instance (Instance

Página 70 - 5-4 Specifications

DeviceNet Information A-21Publication 198-UM001B-EN-P September 200125 Get I/O Error USINT 0 = No error1 = Module added2 = Module removed3 = M

Página 71 - Specifications 5-5

A-22 DeviceNet Information Publication 198-UM001B-EN-P September 2001➊0 = Empty1 = Sensor Module2 = AC Starter Module3 = DC Input Relay Output

Página 73 - 198-IB2S (Sensor Module)

3XEOLFDWLRQ80%(136HSWHPEHU6XSHUVHGHV3XEOLFDWLRQ80$863)HEUXDU\ 5RFNZHOO$XWRPDWLRQ3ULQWHGLQWKH86$

Página 74 - 5-8 Specifications

Installation 2-4Publication 198-UM001B-EN-P September 2001Module InstallationThe I/O System can be mounted either on a DIN Rail or a Gland Pla

Página 75 - Specifications 5-9

2-5 Installation Publication 198-UM001B-EN-P September 2001Gland Plate MountingGland plates may also be referred to as cable plates. These pla

Página 76 - 198-IB4 (4-Input DC Module)

Installation 2-6Publication 198-UM001B-EN-P September 2001ATTENTION!The gland plate must be on a flat secure surface and safety glasses must b

Página 77 - Specifications 5-11

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Página 78 - 5-12 Specifications

2-7 Installation Publication 198-UM001B-EN-P September 2001Figure 2.4 Physical Diagram of Connecting Control Power to I/O ModulesWiring Diagra

Página 79

Publication 198-UM001B-EN-P September 2001Chapter 3OperationChapter ObjectivesThis chapter contains the following information:• Configuring the Modul

Página 80 - 5-14 Specifications

3-2 Publication 198-UM001B-EN-P September 2001To begin the configuration of DeviceNet, execute the RSNetworx software and complete the follow

Página 81 - Specifications 5-15

3-3Publication 198-UM001B-EN-P September 2001RSNetworx will display an icon and the name and node address of each device on the network. The

Página 82 - 198-IA2 (2-Input AC Module)

3-4 Publication 198-UM001B-EN-P September 20012. Select SURSHUWLHV. RSNetworx will verify the identity of the device and then the following s

Página 83 - Specifications 5-17

3-5Publication 198-UM001B-EN-P September 20014. From the screen shown, verify that the number of modules and the name of the modules recogniz

Página 84 - 5-18 Specifications

3-6 Publication 198-UM001B-EN-P September 2001The second way of changing a node address can be done by following the steps shown below.1. Fro

Página 85

3-7Publication 198-UM001B-EN-P September 20013. From this screen select the appropriate PC interface. For our example we will use the 1770-KF

Página 86 - 5-20 Specifications

3-8 Publication 198-UM001B-EN-P September 20015. Choose the desired node address and click the $SSO\button. Click the ([LW button. The unit

Página 87 - Specifications 5-21

3-9Publication 198-UM001B-EN-P September 20012. Select the Parameter tab. RSNetworx will then ask you to upload the parameters from the devi

Página 88

Throughout this manual we use notes to make you aware of safety considerations:Attention statements help you to:• identify a hazard• avoid a hazard• r

Página 89 - Specifications 5-23

3-10 Publication 198-UM001B-EN-P September 20013. To change the settings of a parameter, click the pull down tab on the desired parameter. Fo

Página 90 - 5-24 Specifications

3-11Publication 198-UM001B-EN-P September 2001optimized for minimum length and will have variable length dependent upon the number of modules

Página 91

3-12 Publication 198-UM001B-EN-P September 20012. When the uploading is completed the following screen will appear:3. There is a list that co

Página 92 - 5-26 Specifications

3-13Publication 198-UM001B-EN-P September 20014. Once the MDSA appears in the Scan list box, Select the Download to Scanner button. The follo

Página 93

3-14 Publication 198-UM001B-EN-P September 2001Advanced TopicsRegistering New DevicesA new device appears on the RSNetworx screen as “Unrecog

Página 94 - 5-28 Specifications

3-15Publication 198-UM001B-EN-P September 2001To register a device you must first obtain the EDS file from the above web page. After obtainin

Página 95 - Specifications 5-29

3-16 Publication 198-UM001B-EN-P September 20013. The Registration screen(shown below) should appear. In this screen select 5HJLVWHUDVLQJO

Página 96

3-17Publication 198-UM001B-EN-P September 20015. Click the 1H[Wbutton. The following screen appears:6. Click the 1H[Wbutton. The following

Página 97 - Specifications 5-31

3-18 Publication 198-UM001B-EN-P September 20017. Click the 1H[Wbutton. The following screen appears:8. Click the )LQLVK button. After a sho

Página 98 - 5-32 Specifications

3-19Publication 198-UM001B-EN-P September 2001COS Mask ParameterDouble-click on the Modular DSA device to get to the device parameters menu,

Página 99

Low Voltage DirectiveThis product is also designated to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 60947-

Página 100 - 5-34 Specifications

3-20 Publication 198-UM001B-EN-P September 2001This parameter is used to configure the behavior of the COS connection. If you will be using t

Página 101 - Series A to Series B Changes

3-21Publication 198-UM001B-EN-P September 2001Since this information is dynamically established during the power-up sequence, these parameter

Página 102 - 5-36 Specifications

3-22 Publication 198-UM001B-EN-P September 2001EXAMPLEFigure 3.1 LineupIn the above example you can see that the first module from the left i

Página 103 - Specifications 5-37

3-23Publication 198-UM001B-EN-P September 2001Now that you have obtained the instance numbers for your system, you can begin configuration by

Página 104 - 5-38 Specifications

3-24 Publication 198-UM001B-EN-P September 2001EXAMPLEThe following example will set the Off to On Delay of Input 2 of the AC starter to 8mse

Página 105

3-25Publication 198-UM001B-EN-P September 2001window. This procedure can be repeated for all of the input points for both of the Off to On de

Página 106

3-26 Publication 198-UM001B-EN-P September 2001EXAMPLEThe following example will set the Operate Mode of input 1 of the Sensor module to Inve

Página 107

3-27Publication 198-UM001B-EN-P September 2001Modular DSA system using explicit messaging. Explicit messages contain the following informatio

Página 108 - Output 1

3-28 Publication 198-UM001B-EN-P September 2001Each I/O module contains 4 bits (one nibble) of data. The data is packed into two modules to a

Página 109 - Typical DOL Wiring Series B

3-29Publication 198-UM001B-EN-P September 2001X = ReservedTable 3.G Instance 104 Data Format for Output AssemblyModule Byte Bit 7 Bit 6 Bit 5

Página 110 - Bulletin 190 Compact Starter

Publication 198-UM001B-EN-P September 2001PrefaceManual ObjectivesThe purpose of this manual is to provide you with the necessary information to appl

Página 111 - Series B Module

3-30 Publication 198-UM001B-EN-P September 2001X = ReservedTable 3.I Instance 105 Data Format for Input AssemblyModule Byte Bit 7 Bit 6 Bit 5

Página 112 - 5-46 Specifications

3-31Publication 198-UM001B-EN-P September 2001Refer to Appendix A for a more detailed description of each attribute shown in the tables above

Página 113 - Specifications 5-47

3-32 Publication 198-UM001B-EN-P September 2001I/O Status LEDThe I/O status LED is a bi-colored (red/green) LED that provides status informat

Página 114

3-33Publication 198-UM001B-EN-P September 2001Table 3.L I/O Status LEDFor This State: I/O Status LED is: To indicate:Off Off No power or All

Página 115 - 120/240V ac

Publication 198-UM001B-EN-P September 2001Chapter 4ProgrammingChapter ObjectivesThis chapter will provide an overview of the steps necessary to use d

Página 116 - 5-50 Specifications

Programming 4-2Publication 198-UM001B-EN-P September 2001The following is the default input assembly for the Cat. No. 198-DNG DeviceNet Contro

Página 117 - 120/240 V AC

4-3 Programming Publication 198-UM001B-EN-P September 2001To map the assemblies to the SLC, we first double click on the scanner icon in RSNet

Página 118 - Series B module

Programming 4-4Publication 198-UM001B-EN-P September 2001The MDSA will be displayed in the scanlist if it has been mapped correctly. Once you

Página 119 - Specifications 5-53

4-5 Programming Publication 198-UM001B-EN-P September 2001To edit the I/O parameters we click the 6FDQOLVWtab and select the (GLW,23DUDPHW

Página 120 - 5-54 Specifications

Programming 4-6Publication 198-UM001B-EN-P September 2001Verifying the Output AssemblyTo verify the output assembly select the 2XWSXWWDE. The

Página 121

2 Preface Publication 198-UM001B-EN-P September 2001VocabularyNote the following references throughout this manual:• Bulletin 198 with its opt

Página 122 - 5-56 Specifications

4-7 Programming Publication 198-UM001B-EN-P September 2001To edit the I/O parameters, click the 6FDQOLVWtab and select the (GLW,23DUDPHWHU

Página 123 - DRIVE MODULE

Programming 4-8Publication 198-UM001B-EN-P September 2001Programming Explicit MessagesNow that the input and output assemblies are mapped corr

Página 124

4-9 Programming Publication 198-UM001B-EN-P September 2001You will then be asked to enter a name for your driver choose a name and select 2..

Página 125

Programming 4-10Publication 198-UM001B-EN-P September 2001The configure screen will appear; select the &ORVH button. The following screen

Página 126 - 5-60 Specifications

4-11 Programming Publication 198-UM001B-EN-P September 2001In the above screen highlight the driver you have configured. Go to &RPPXQLFDWL

Página 127

Programming 4-12Publication 198-UM001B-EN-P September 2001Next you will have to configure the I/O. Double click on ,2&RQILJXUDWLRQ under

Página 128 - 5-62 Specifications

4-13 Programming Publication 198-UM001B-EN-P September 2001Close window and begin coding for the program. An example program in which an MDSA

Página 129

Publication 198-UM001B-EN-P September 2001Chapter 5Specifications198-DNG, 198-DN (DeviceNet Modules)Figure 5.1 198-DNG and 198-DN DeviceNet ModulesTh

Página 130

5-2 Specifications Publication 198-UM001B-EN-P September 2001Table 5.A Mod/Net Status LEDFor this state: MS/NS LED is: To indicate:Powerup and

Página 131

Specifications 5-3Publication 198-UM001B-EN-P September 2001I/O Status LEDThe I/O status LED is a bi-colored (red/green) LED that provides sta

Página 132 - 5-66 Specifications

Table of ContentsPrefaceManual Objectives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 133 - 198-G1P (Gland Plates)

5-4 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.2 198-DN and 198-DNG Electrical and Application SchematicCANH (White) (4

Página 134 - 5-68 Specifications

Specifications 5-5Publication 198-UM001B-EN-P September 2001Table 5.C 198-DN and 198-DNG General SpecificationsTerminal Block (5.08 mm Pitch 5

Página 135

5-6 Specifications Publication 198-UM001B-EN-P September 2001198-DNP (Mini DIN Pass-Through)The 198-DNP is designed to provide a connection fr

Página 136 - 5-70 Specifications

Specifications 5-7Publication 198-UM001B-EN-P September 2001198-IB2S (Sensor Module)Figure 5.4 198-IB2S Sensor ModuleThe sensor input module 1

Página 137 - Troubleshooting

5-8 Specifications Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 an

Página 138 - Low DeviceNet Voltage

Specifications 5-9Publication 198-UM001B-EN-P September 2001➊These specifications are for reference only. Refer to sensor specification for ex

Página 139 - Discontinuity Error

5-10 Specifications Publication 198-UM001B-EN-P September 2001198-IB4 (4-Input DC Module)Figure 5.6 198-IB4 4-Input DC ModuleThe 4-input DC mo

Página 140 - Sensor Undervoltage Error

Specifications 5-11Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 an

Página 141 - DeviceNet Information

5-12 Specifications Publication 198-UM001B-EN-P September 2001Table 5.H 198-IB4 SpecificationsTerminal Block (5.08 mm Pitch 6-Position — Serie

Página 142 - Operating Modes

Specifications 5-13Publication 198-UM001B-EN-P September 2001198-IB4S Series A (4-Input DC Module DS)Figure 5.8 198-IB4S Series A 4-Input DC M

Página 143 - Error Mode

ii Table of Contents Publication 198-UM001B-EN-P September 2001Chapter 4 — ProgrammingChapter Objectives . . . . . . . . . . . . . . . . . . .

Página 144 - Object Definitions

5-14 Specifications Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 a

Página 145

Specifications 5-15Publication 198-UM001B-EN-P September 2001Table 5.J 198-IB4S SpecificationsTerminal Block (3.5 mm Pitch 8-Position)Connecti

Página 146

5-16 Specifications Publication 198-UM001B-EN-P September 2001198-IA2 (2-Input AC Module)Figure 5.10 198-IA2 2-Input AC ModuleThe 2-input AC m

Página 147 - Table A.9 Input Assemblies

Specifications 5-17Publication 198-UM001B-EN-P September 2001Figure 5.11 198-IA2 Electrical and Application SchematicTable 5.L 198-IA2 Specifi

Página 148

5-18 Specifications Publication 198-UM001B-EN-P September 2001EnvironmentalAmbient Temperature Operating –25…+60°C (–4…+140°F)Storage –40…+85°

Página 149

Specifications 5-19Publication 198-UM001B-EN-P September 2001198-IA2-G4 Series A (AC Sensor Module)Figure 5.12 198-IA2-G4 Series A AC Sensor M

Página 150 - Output Assembly Instance 102

5-20 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.13 198-IA2-G4 Electrical and Application Schematic120V AC214PEPELNIN 1I

Página 151 - Input Assembly Instance 101

Specifications 5-21Publication 198-UM001B-EN-P September 2001Table 5.N 198-IA2-G4 Series A SpecificationsTerminal Block (5.08 mm Pitch 4-Posit

Página 152 - Input Assembly Instance 103

5-22 Specifications Publication 198-UM001B-EN-P September 2001198-IA1-G4 9000 Series A (9000 Sensor Module)Figure 5.14 198-IA1-G4 9000 Series

Página 153 - Input Assembly Instance 105

Specifications 5-23Publication 198-UM001B-EN-P September 2001Assembly Instances 104 and 105 are default for 198-DNG. Assembly Instances 106 an

Página 154 - Input Assembly Instance 107

Table of Contents iiiPublication 198-UM001B-EN-P September 2001Sensor Undervoltage Error . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 155 - Module Error Number

5-24 Specifications Publication 198-UM001B-EN-P September 2001Table 5.P 198-IA1-G4 9000 Series A SpecificationsTerminal Block (5.08 mm Pitch 4

Página 156 - Table A.21 Error Code

Specifications 5-25Publication 198-UM001B-EN-P September 2001198-OW2S (2-Relay Output Gland)Figure 5.16 198-OW2S 2-Relay Output GlandThe relay

Página 157

5-26 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.17 198-OW2S Electrical and Application SchematicTable 5.R 198-OW2S Spec

Página 158

Specifications 5-27Publication 198-UM001B-EN-P September 2001198-OW2 Series A (2-Relay Output DIN Module)Figure 5.18 198-OW2 Series A 2-Relay

Página 159

5-28 Specifications Publication 198-UM001B-EN-P September 2001Figure 5.19 198-OW2 Electrical and Application SchematicTable 5.T 198-OW2 Specif

Página 160

Specifications 5-29Publication 198-UM001B-EN-P September 2001EnvironmentalAmbient Temperature Operating –25…+60°C (–4…+140°F)Storage –40…+85°C

Página 161

5-30 Specifications Publication 198-UM001B-EN-P September 2001198-OW2-G4 Series A (Relay Valve Module)Figure 5.20 198-OW2-G4 Series A Relay Va

Página 162

Specifications 5-31Publication 198-UM001B-EN-P September 2001Figure 5.21 198-OW2-G4 Electrical and Application SchematicTable 5.V 198-OW2-G4 S

Página 163

5-32 Specifications Publication 198-UM001B-EN-P September 2001EnvironmentalAmbient Temperature Operating –25…+60°C (–4…+140°F)Storage –40…+85°

Página 164

Specifications 5-33Publication 198-UM001B-EN-P September 2001198-OW2S-Q5 Series A (DeviceNet Valve Module)Figure 5.22 198-OW2S-Q5 Series A Dev

Comentários a estes Manuais

Sem comentários