10 High Current 8 Input/8 Output ArmorBlock I/O Module Series B
Publication 1792D-IN005D-EN-P - February 2002
Change-of-State - productions occur when an input changes or a
fault condition occurs. If no input or fault condition change occurs
within the expected packet rate, a heartbeat production occurs. This
heartbeat production tells the scanner module that the I/O module is
alive and ready to communicate. Consumption occurs when data
changes and the master produces new input data to the I/O block.
Refer to the table below for the word/bit definitions.
Refer to the table below for byte/bit descriptions.
The DeviceNet Network uses advanced network technology,
producer/consumer communication, to increase network
functionality and throughput. Visit our web site at
http://www.ab.com/networks
for producer/consumer technology
information and updates.
Bit 0706050403020100
Produces 0 OL7 OL6 0L5 0L4 0L3 0L2 0L1 0L0
Produces 1 NL7 NL6 NL5 NL4 NL3 NL2 NL1 NL0
Produces 2 I7 I6 I5 I4 I3 I2 I1 I0
Consumes 0 O7 O6 O5 O4 O3 O2 O1 O0
Where: OL=Output Overload NL=Output No Load I=Input O = Output
Byte Bit Description
Produces 0 00-07 Output overload status
Produces 1 00-07 Output no load status
Produces 2 00-07 Input point status
Consumes 0 00-07 Output bits: When the bit is set (1), the output will
be turned on. Bit 00=output 00, bit 01=output 01,
bit 02=output 02, bit 03=output 03, bit 04=output
04, bit 05=output 05, bit 06=output 06, bit
07=output 07.