Rockwell-automation 1746-BAS-T SLC 500 Basic Module/ Instructions Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 1746-BAS-T SLC 500 Basic Module/ Instructions. Rockwell Automation 1746-BAS-T SLC 500 Basic Module/ Instructions Manuel d'utilisation Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 28
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Publication 1746-IN009B-EN-P - August 2005
Installation Instructions
SLC 500 BASIC and BASIC-T Modules
Catalog Numbers 1746-BAS and 1746-BAS-T
Inside . . .
For See Page
Important User Information 2
Hazardous Location Considerations 3
Environnements dangereux 3
About the BASIC and BASIC-T Modules 4
Before You Begin 5
Install the 1746-BAS Module and 1746-BAS-T
Module
12
Wire the PRT1 and PRT2 Communication Ports 13
Wire to the DH485 Port 18
Apply Power to your BASIC Module and
BASIC-T Modules
19
Configure the BASIC Module and BASIC-T
Module
19
Battery Replacement, Handling, Storage, and
Transportation (Cat. No. 1747-BA)
20
Specifications 24
Additional Resources 26
Vista de página 0
1 2 3 4 5 6 ... 27 28

Resumo do Conteúdo

Página 1 - Inside . .

Publication 1746-IN009B-EN-P - August 2005Installation InstructionsSLC 500 BASIC and BASIC-T ModulesCatalog Numbers 1746-BAS and 1746-BAS-TInside . .

Página 2 - Important User Information

10 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Figure 5 Jumper JW3 Pin Assignments and SettingsModule Jumper JW4Use

Página 3 - Environnements dangereux

SLC 500 BASIC and BASIC-T Modules 11Publication 1746-IN009B-EN-P - August 2005Figure 6 Jumper JW4 Pin Assignments and SettingsIMPORTANTWhen DF1 pr

Página 4

12 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Install the 1746-BAS Module and 1746-BAS-T ModuleYour BASIC module o

Página 5 - Before You Begin

SLC 500 BASIC and BASIC-T Modules 13Publication 1746-IN009B-EN-P - August 2005Wire the PRT1 and PRT2 Communication PortsPorts PRT1 and PRT2 can co

Página 6

14 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Hardware HandshakingThe module uses the following rules when hardwar

Página 7 - Set the Module Jumpers

SLC 500 BASIC and BASIC-T Modules 15Publication 1746-IN009B-EN-P - August 2005DCE - Data Communication EquipmentDevices such as modems are Data Co

Página 8 - Module Jumper JW1

16 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Figure 8 RS-232/423 Wiring Diagram - 1746-BAS Module or 1746-BAS-T M

Página 9 - Module Jumper JW3

SLC 500 BASIC and BASIC-T Modules 17Publication 1746-IN009B-EN-P - August 2005Figure 10 RS-232/423 Wiring Diagram - 1746-BAS Module or 1746-BAS-T

Página 10 - Module Jumper JW4

18 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Wire to the DH485 PortPort DH485 can communicate to user devices thr

Página 11

SLC 500 BASIC and BASIC-T Modules 19Publication 1746-IN009B-EN-P - August 2005Apply Power to your BASIC Module and BASIC-T ModulesOnce you have in

Página 12 - Module Release

2 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Important User InformationSolid state equipment has operational chara

Página 13 - Pin Assignments

20 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005B a t t e r y R e p l a c e m e n t , H a n d l i n g , S t o r a

Página 14 - DTE and DCE Overview

SLC 500 BASIC and BASIC-T Modules 21Publication 1746-IN009B-EN-P - August 2005Figure 15 Battery Location3. Unplug the battery connector.4. Remove

Página 15

22 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Battery StorageStore the lithium batteries in a cool, dry environmen

Página 16

SLC 500 BASIC and BASIC-T Modules 23Publication 1746-IN009B-EN-P - August 2005For disposal, batteries must be packaged and shipped in accordance w

Página 17

24 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005SpecificationsBASIC and BASIC-T Modules SpecificationsSpecification

Página 18 - Wire to the DH485 Port

SLC 500 BASIC and BASIC-T Modules 25Publication 1746-IN009B-EN-P - August 2005Operating Voltage and Current RequirementComponent Operating Voltage

Página 19

26 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Additional ResourcesTo view and download pdfs, go to Literature Libr

Página 20 - (Cat. No. 1747-BA)

SLC 500 BASIC and BASIC-T Modules 27Publication 1746-IN009B-EN-P - August 2005

Página 21 - Battery Handling

Publication 1746-IN009B-EN-P - August 2005 PN 40071-092-01(3)Supersedes Publication 1746-IN009A-EN-P - March 2000 Copyright © 2007 Rockwell Automation

Página 22 - Battery Transportation

SLC 500 BASIC and BASIC-T Modules 3Publication 1746-IN009B-EN-P - August 2005Hazardous Location ConsiderationsThis equipment is suitable for use i

Página 23

4 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005About the BASIC and BASIC-T ModulesThe BASIC module is a single-slot

Página 24 - Specifications

SLC 500 BASIC and BASIC-T Modules 5Publication 1746-IN009B-EN-P - August 2005Before You BeginBefore you begin to install the BASIC module and BASI

Página 25

6 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Figure 1 Communication Ports and LED Indicators LED Color Status Indi

Página 26 - Additional Resources

SLC 500 BASIC and BASIC-T Modules 7Publication 1746-IN009B-EN-P - August 2005Set the Module JumpersThe BASIC module and BASIC-T module have four s

Página 27

8 SLC 500 BASIC and BASIC-T ModulesPublication 1746-IN009B-EN-P - August 2005Module Jumper JW1Use jumper JW1 to select one of the following config

Página 28 - Automation, Inc

SLC 500 BASIC and BASIC-T Modules 9Publication 1746-IN009B-EN-P - August 2005Module Jumper JW2Use jumper JW2 to select one of the following config

Comentários a estes Manuais

Sem comentários