Rockwell-automation 1608P-200A480V... HC-DySC User Manual Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 1608P-200A480V... HC-DySC User Manual. Rockwell Automation 1608P-200A480V... HC-DySC User Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 45
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Bulletin 1608P HC-DySC Dynamic Voltage Sag Corrector
1608P-200A480V...-HC and 1608P-200A480V...-GT Models
User Manual
Vista de página 0
1 2 3 4 5 6 ... 44 45

Resumo do Conteúdo

Página 1 - User Manual

Bulletin 1608P HC-DySC Dynamic Voltage Sag Corrector1608P-200A480V...-HC and 1608P-200A480V...-GT ModelsUser Manual

Página 2 - Additional Resources

10 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 2 Installation 3-Wire vs. 4-Wire ConfigurationsHC-DySC models are availabl

Página 3 - Ch 5 - Display Screen

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 11Installation Chapter 24- Wire ModelsBulletin 1608P part numbers containing V4 are

Página 4 - Transfer (GT) Option

12 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 2 InstallationElectrical Terminations and RatingsInput connections are mar

Página 5 - Introduction

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 13Chapter 3CommunicationsBoth dry contacts (relays) that indicate status and a Seria

Página 6

14 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 3 CommunicationsSerial Communications PortThe HC-DySC serial port is a DE-

Página 7 - Installation

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 15Chapter 4Applying Power and OperationApplying Power• Before applying power to the

Página 8 - Recommendations

16 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 4 Applying Power and OperationHC-DySC System OperationSystem DescriptionTh

Página 9 - Accessing Terminations

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 17Applying Power and Operation Chapter 4Bypass Switch ModesThe maintenance bypass sw

Página 10 - 3- Wire Models

18 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 4 Applying Power and OperationTest ModeThe TEST mode for the HC-DySC is fo

Página 11 - 4- Wire Models

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 19Applying Power and Operation Chapter 4HC-DySC OperationThe HC-DySC section contain

Página 12 - Electrical Terminations and

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Página 13 - Communications

20 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 4 Applying Power and OperationA list of conditions and indications is give

Página 14 - Serial Communications Port

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 21Chapter 5Display ScreenOverview The HC-DySC® touch screen display is a window to v

Página 15 - Applying Power and Operation

22 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 5 Display ScreenNote: To recalibrate from any screen, hold anywhere on the

Página 16 - Operation

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 23Display Screen Chapter 5Home Screen The “HOME” screen of the display provides a sn

Página 17 - Bypass Switch Modes

24 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 5 Display ScreenSystem Status The “System Status” screen displays the real

Página 18 - Procedure

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 25Display Screen Chapter 5Voltage Sag Events A voltage sag is defined as the period

Página 19 - HC-DySC Operation

26 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 5 Display ScreenVoltage Sag Detail Vo lta g e Sa g Deta il” screen (See F

Página 20 - LINE < 88.5% for less

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 27Display Screen Chapter 5Voltage Sag RMS Voltage Charts The line and load RMS volta

Página 21 - Display Screen

28 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 5 Display ScreenSystem Events The HC-DySC tracks all operational events wh

Página 22 - Step 3: The “Touch Screen

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 29Display Screen Chapter 5System Event Detail The “System Event Detail” screen is di

Página 23 - Mechanical Bypass

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 3Table of ContentsImportant User Information. . . . . . . . . . . . . . . . . . . .

Página 24 - Description Function

30 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 5 Display ScreenSystem Event Notification When the HC-DySC system first de

Página 25 - Voltage Sag Log

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 31Display Screen Chapter 5System Configuration Press the “CONFIG” button at the bott

Página 26

32 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 5 Display ScreenRun System TestsPress the “RUN SYSTEM TESTS” to enter the

Página 27 - Voltage Sag RMS Voltage

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 33Chapter 6MaintenancePreventative MaintenanceThe HC-DySC requires very little preve

Página 28 - System Event Log

34 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 6 MaintenanceTable 11 - System Event TableEventCode Code Name Full Name S

Página 29 - Table 9 - System Event Detail

35 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 6 Maintenance36COM_VERStart-Up Test: Communication Compatibility Mismatch

Página 30 - System Event Notification

36 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 6 MaintenanceServicingBefore attempting any servicing that requires openin

Página 31 - Table 10 - Model Information

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 37Maintenance Chapter 6Fuse locations within the HC-DySC cabinet are shown on a labe

Página 32 - Diagnostics Mode

38 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 6 MaintenanceTransient Voltage Surge Suppressor (TVSS)The HC-DySC includes

Página 33 - Maintenance

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 39Chapter 7Specifications and Dimensions Table 13 - Technical Specifications 200 A H

Página 34 - Table 11 - System Event Table

4 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Table of ContentsCh 6 - MaintenancePreventative Maintenance . . . . . . . . . . .

Página 35

40 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 7 Specifications and DimensionsTable 14 - Heat DissipationApproximate Dime

Página 36 - Servicing

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 41Appendix AHC-DySC with Generator Transfer (GT) OptionGT Option DescriptionHC-DySC

Página 37 - Fuse Rating Charts

42 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Appendix A HC-DySC with Generator Transfer (GT) OptionFigure 31 - Home Screen GT M

Página 38 - Chapter 6 Maintenance

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 43HC-DySC with Generator Transfer (GT) Option Appendix ATypical TB2 connections for

Página 39 - Chapter 7

44 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Appendix A HC-DySC with Generator Transfer (GT) OptionNotes:

Página 40 - Approximate Dimensions

Publication 1608P-UM005A-EN-P - November 2014 Copyright © 2014 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.ADIR 10001354233Rockw

Página 41 - GT Option Operation

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 5Chapter 1Introduction The Allen-Bradley Bulletin 1608P HC-DySC Dynamic Sag Correcto

Página 42 - ATS / Generator Contacts

6 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 1ATTENTION: - To reduce the risk of fire or electric shock, install this HC

Página 43 - Indicator

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 7Chapter 2Installation Installation Check ListBefore proceeding, take a few minutes

Página 44

8 Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014Chapter 2 Installation Floor MountingSecure the HC-DySC to the floor using fastener

Página 45 - Documentation Feedback

Rockwell Automation Publication 1608P-UM005A-EN-P - November 2014 9Installation Chapter 2Electrical TerminationsUse a qualified electrician to install

Comentários a estes Manuais

Sem comentários