Rockwell-automation 1606-XLSBUFFER24 Power Supply Reference Manual Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 1606-XLSBUFFER24 Power Supply Reference Manual. Rockwell Automation 1606-XLSBUFFER24 Power Supply Reference Manual User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 14
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Reference Manual
Bulletin 1606 Switched Mode Power Supplies
Catalog Number: 1606-XLSBUFFER24
Index
1. Description
.........................................,............................. 1
2.
Specication Quick Reference ................................... 1
3.
Catalog Numbers ............................................................. 1
4. Certication Marks ........................................................... 1
5. Standby Mode ................................................................. 4
6. Charging Mode .............................................................. 4
7. Buer Mode ..................................................................... 5
8. Functional Diagram ...................................................... 6
9. Front Side and User Elements ................................ 6
10. Operating Diagram ...................................................... 7
11. Active and Ready Signal, Inhibit Input ............. 7
12.
Terminals and Wiring ................................................ 8
13. Reliability .................................................................... 8
14. EMC ................................................................................ 9
15. Environment ............................................................. 9
16. Protection Features ............................................ 10
17. Safety .......................................................................... 10
18. Certications
............................................................. 10
19. Physical Dimensions and Weight ............... 11
20. Wiring Diagrams .................................................. 12
Mounting Orientation—The power terminal shall be located on top of the unit.
Cooling—Convection cooled, no forced air cooling required. Do not obstruct air flow!
Recommended Installation Clearances—40mm on top of unit; 20mm on bottom of unit; 0mm (or 15mm if adjacent device is a heat source) on
the left and right sides of the unit.
Intended Use—This buffer unit is designed for use in panel board installations or other in-building applications where a suitable mechanical
enclosure is provided to fulfil local requirements.
Service PartsThis unit does not contain any service part. Should damage or malfunction occur during installation, turn power off immediately and
return unit to the manufacturer for inspection.
Installation Notes
Vista de página 0
1 2 3 4 5 6 ... 13 14

Resumo do Conteúdo

Página 1 - Reference Manual

Reference ManualBulletin 1606 Switched Mode Power SuppliesCatalog Number: 1606-XLSBUFFER24Index1. Description...

Página 2 - 4. Certication Marks

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.10 Rockwell Automation Publication 16

Página 3 - Installation Requirements

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.Rockwell Automation Publication 1606-

Página 4 - 6. Charging Mode

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.12 Rockwell Automation Publication 16

Página 6 - 8. Functional Diagram

Rockwell Automation SupportRockwell Automation provides technical information on the Web to assist you in using its products. At http://www.rockwellau

Página 7 - 10. Operating Diagram

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.2 Rockwell Automation Publication 160

Página 8 - 13. Reliability

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.Rockwell Automation Publication 1606-

Página 9 - 15. Environment

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.4 Rockwell Automation Publication 160

Página 10 - 18. Certications

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.Rockwell Automation Publication 1606-

Página 11 - Weight 740g / 1.63lb

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.6 Rockwell Automation Publication 160

Página 12 - 20. Wiring Diagrams

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.Rockwell Automation Publication 1606-

Página 13

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.8 Rockwell Automation Publication 160

Página 14 - Rockwell Automation Support

All parameters are specified at 24V, 20A, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.Rockwell Automation Publication 1606-

Comentários a estes Manuais

Sem comentários