Rockwell-automation 1403-DM_LM_MM Powermonitor II Instruction Sheet Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 1403-DM_LM_MM Powermonitor II Instruction Sheet. Rockwell Automation 1403-DM_LM_MM Powermonitor II Instruction Sheet User Manual [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 88
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Publication 1403-IN001A-US-P
Instruction Sheet
Bulletin 1403 Powermonitor II
(Cat. No. 1403-MM, 1403-LM, 1403-DM)
Cat. No. 1403-DM
Cat. No. 1403-MM, 1403-LM
Vista de página 0
1 2 3 4 5 6 ... 87 88

Resumo do Conteúdo

Página 1 - Bulletin 1403 Powermonitor II

Publication 1403-IN001A-US-PInstruction SheetBulletin 1403 Powermonitor II(Cat. No. 1403-MM, 1403-LM, 1403-DM)Cat. No. 1403-DMCat. No. 1403-

Página 2 - Important User Information

1-2 Product Description1403-IN001A-US-PQuick Start - Minimum Device ConfigurationAt a minimum, the following steps MUST be followed for proper operati

Página 3 - Table of Contents

Product Description 1-31403-IN001A-US-PCommunicationsBoth versions of the Powermonitor II can use the 1403-NSC Smart Communications Card for communica

Página 4 - General Operation Chapter 4

1-4 Product Description1403-IN001A-US-PData LoggingThe Powermonitor II provides three data logs: the Event log, the Min/Max log, and the Snapshot log.

Página 5 - Glossary Appendix D

1403-IN001A-US-PChapter 2InstallationPrevent Electrostatic DischargeMounting of Master ModuleProtective Enclosure A suitable enclosure should be used

Página 6

2-2 Installation1403-IN001A-US-PWiring of Master ModuleTerminal Blocks Wire Sizes and Screw Torques Observe all wire lug sizes and screw torques. Refe

Página 7 - Using This Instruction

Installation 2-31403-IN001A-US-PUse instrument accuracy PTs when the voltage levels being measured exceed the voltage input ratings. The PT accuracy r

Página 8 - Terms and Conventions

2-4 Installation1403-IN001A-US-PFigure 2.2 Single Phase Direct Connection Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S4ScomL/+R14R11R12R24R2

Página 9 - Product Description

Installation 2-51403-IN001A-US-PFigure 2.3 Single Phase with PTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S4ScomL/+R14R11R12R24R21R22AcomA

Página 10 - Displays

2-6 Installation1403-IN001A-US-PFigure 2.4 3-phase 4-wire Wye Direct Connect Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S4ScomL/+R14R11R12R2

Página 11 - Status Inputs

Installation 2-71403-IN001A-US-PFigure 2.5 3-phase 4-wire with PTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S4ScomL/+R14R11R12R24R21R22Ac

Página 12 - Operational Characteristics

Publication 1403-IN001A-US-PImportant User InformationSolid-state equipment has operational characteristics differing from those of electromechanica

Página 13 - Installation

2-8 Installation1403-IN001A-US-PFigure 2.6 3-phase 3-wire Grounded Wye Direct Connection Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S4ScomL/

Página 14 - Wiring of Master Module

Installation 2-91403-IN001A-US-PFigure 2.7 3-phase 3-wire Grounded Wye with PTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I1±I2+I2±I3+I3±I4+I4±S1S2S3S4Sco

Página 15 - 1403-IN001A-US-P

2-10 Installation1403-IN001A-US-PFigure 2.8 3-phase 3-wire Delta with Three PTs and Three CTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S4S

Página 16

Installation 2-111403-IN001A-US-PFigure 2.9 3-phase 3-wire Open Delta with Two PTs and Three CTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3

Página 17

2-12 Installation1403-IN001A-US-PFigure 2.10 3-phase 3-wire Open Delta with Two PTs and Two CTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S

Página 18

Installation 2-131403-IN001A-US-PFigure 2.11 3-phase 3-wire Grounded L2(B) Phase Open Delta Direct Connect with Three CTs Wiring DiagramV1V2V3NFiberRx

Página 19

2-14 Installation1403-IN001A-US-PFigure 2.12 3-phase 3-wire Delta Direct Connect with Three CTs Wiring DiagramV1V2V3NFiberRxFiberTxI1+I2+I3+I4+S1S2S3S

Página 20 - Wiring Diagram

Installation 2-151403-IN001A-US-PFigure 2.13 3-phase 3-wire Delta Direct Connect with Three CTs Wiring DiagramV1V2V3NFiberRxS1S2S3S4ScomL/+R14R11R12R2

Página 21

2-16 Installation1403-IN001A-US-PAnalog InputThis input is intended to accept input signals of zero to one volt AC, 50/60 Hz, rms or plus/minus (±) 1.

Página 22 - CTs Wiring Diagram

Installation 2-171403-IN001A-US-PIsolation Voltage 2500V status input to case 2500V status input to internal digital circuitryFigure 2.15 Status Input

Página 23 - Three CTs Wiring Diagram

1403-IN001A-US-PTable of ContentsUsing This Instruction Sheet PrefaceWhat This Instruction Sheet Contains. . . . . . . . . . . . . . . . . . . . . . .

Página 24 - Two CTs Wiring Diagram

2-18 Installation1403-IN001A-US-PWiring of Display ModuleNote: All ground wires should be kept as short as possible; 30cm (12 in.) or less is suggeste

Página 25

Installation 2-191403-IN001A-US-PFiber Optic Cable Assembly Strain Relief A strain relief feature at the rear of the Display Module and a wire tie are

Página 26

2-20 Installation1403-IN001A-US-PCommunication ConnectionsThe Powermonitor II Master Module uses a communications connector for all Communications Car

Página 27

1403-IN001A-US-PChapter 3MaintenanceBattery Installation and Replacement ProceduresInstallationNote: For proper operation, the device should not be po

Página 28

3-2 Maintenance1403-IN001A-US-PFigure 3.2 Master Module with Battery Installed4. Reinstall the access cover plate on the top face of the Master Module

Página 29 - LED Indicators

Maintenance 3-31403-IN001A-US-P4. Refer to Battery Installation and Replacement Procedures on page 3-1 for installation of a new battery.5. Reinstall

Página 30 - Wiring of Display Module

3-4 Maintenance1403-IN001A-US-P

Página 31 - Installation 2-19

1403-IN001A-US-PChapter 4General OperationGeneral FunctionalityThe Display Module acts as a simple terminal that allows a user to easily view metering

Página 32 - Communication Connections

4-2 General Operation1403-IN001A-US-PNote: For additional information on measured parameters listed in Chapter 4, refer to Publication 1403-1.0.2, Bul

Página 33 - Maintenance

General Operation 4-31403-IN001A-US-PIssuing a Command1. Using the four Display Module keys, move into Program mode and display the command to be issu

Página 34 - 3-2 Maintenance

1403-IN001A-US-PiiMaintenance Chapter 3Battery Installation and Replacement Procedures . . . . . . . . . . . . . . . . . . 3-1Installation . . . . . .

Página 35 - Field Service Considerations

4-4 General Operation1403-IN001A-US-PFigure 4.2 Menu/Parameter StructureProgramPassword?Program3-phase L-N V / IPhase 1 L-N V / IPhase 2 L-N V / IPhas

Página 36 - 3-4 Maintenance

General Operation 4-51403-IN001A-US-PK-factor V / I①Crest V / I①TIF V / I①IEEE-519 V / I①IEEE %THD V / IIEC %THD V / IHarmonic 1/2 V / I①Harmonic 39/4

Página 37 - General Operation

4-6 General Operation1403-IN001A-US-PConfiguration ItemsGeneralTable 4.1 displays the General Configuration items for Powermonitor II. The gray scale

Página 38 - Editing a Digital Parameter

General Operation 4-71403-IN001A-US-PSnapshot Buffer Type The buffer type used by the snapshot log. Fill and Stop stops filling the buffer when it is

Página 39 - Issuing a Command

4-8 General Operation1403-IN001A-US-PChannel A 12-Cycle Oscillograph¨Used to select which of the seven input channels is captured for channel A when a

Página 40 - 4-4 General Operation

General Operation 4-91403-IN001A-US-PDemandTable 4.2 displays the Demand Configuration items for Powermonitor II. The gray scale indicates which param

Página 41 - General Operation 4-5

4-10 General Operation1403-IN001A-US-PCommandsTable 4.3 displays the commands for the Powermonitor II. The gray scale indicates which commands are ava

Página 42 - Configuration Items

General Operation 4-111403-IN001A-US-PMeteringVoltage/CurrentTable 4.4 displays the Voltage and Current Metering information provided by the Powermoni

Página 43 - General Operation 4-7

4-12 General Operation1403-IN001A-US-PPowerTable 4.5 displays the Power Metering information provided by the Powermonitor II. The gray scale indicates

Página 44 - 4-8 General Operation

General Operation 4-131403-IN001A-US-PPhase 2 Distortion Power Factor The ratio between the magnitude of the fundamental and the sum of the magnitudes

Página 45 - General Operation 4-9

1403-IN001A-US-PiiiMaster Module Data Acquisition Status . . . . . . . . . . . . . . . . . . . . . 4-29Master Module Watchdog Timer Status. . . . . .

Página 46 - Commands

4-14 General Operation1403-IN001A-US-PCumulative PowerTable 4.6 displays the Cumulative Power Metering information provided by the Powermonitor II. Th

Página 47 - Metering

General Operation 4-151403-IN001A-US-PHarmonic AnalysisTable 4.7 displays the Harmonic Analysis information provided by the Powermonitor II. The gray

Página 48

4-16 General Operation1403-IN001A-US-PSetpointsTheory of Setpoint OperationThe Powermonitor II is capable of monitoring many parameters (simultaneousl

Página 49 - General Operation 4-13

General Operation 4-171403-IN001A-US-POver Reverse SetpointAn over reverse setpoint is the same as an over forward setpoint, except the magnitude of t

Página 50 - Cumulative Power

4-18 General Operation1403-IN001A-US-PUnder Forward SetpointAn under forward setpoint is the same as an over forward setpoint, except the “Setpoint Hi

Página 51 - Harmonic Analysis

General Operation 4-191403-IN001A-US-PUnder Reverse SetpointAn under reverse setpoint is the same as an under forward setpoint, except the magnitude o

Página 52 - Setpoints

4-20 General Operation1403-IN001A-US-PTable 4.8 Setpoint ConfigurationParameter Name Parameter Description Range DefaultSetpoint Number The number of

Página 53 - Over Reverse Setpoint

General Operation 4-211403-IN001A-US-PTable 4.9 Setpoint TypeSetpointTypeDescription0 Not used (inactive)1 Voltage (any 1 of three phases, L-N in Sing

Página 54 - Under Forward Setpoint

4-22 General Operation1403-IN001A-US-PExamples of Setpoint OperationSetpoint Example 1 - Over kW Forward (+)If it is desired that setpoint 1 energizes

Página 55 - Figure 4.7 Under Reverse

General Operation 4-231403-IN001A-US-PData LoggingThe Powermonitor II provides three data logs: •Event log•Snapshot log•Min/Max log Each record of the

Página 57 - General Operation 4-21

4-24 General Operation1403-IN001A-US-PWhenever a setpoint event occurs, the setpoint setup information is also logged. This information is viewed via

Página 58 - Relay Operation

General Operation 4-251403-IN001A-US-PTable 4.13 Snapshot Log Parameters for the Voltage and Current BlockParameter Description Range DefaultPhase 1 L

Página 59

4-26 General Operation1403-IN001A-US-PTable 4.14 Snapshot Log Parameters for the Power BlockParameter Description Range DefaultPhase 1 Power Power of

Página 60 - Snapshot Log

General Operation 4-271403-IN001A-US-PMin/Max LogThe Min/Max log records the minimum and maximum values for 84 parameters. These parameters are listed

Página 61 - General Operation 4-25

4-28 General Operation1403-IN001A-US-POscillography (1403-MM only)The Powermonitor II provides two types of oscillography. Both are triggered simultan

Página 62 - 4-26 General Operation

General Operation 4-291403-IN001A-US-POverall StatusThe overall status word is a summary of the individual self-test summary status bits. This allows

Página 63 - Min/Max Log

4-30 General Operation1403-IN001A-US-PReal Time Clock StatusBattery Usage Timer ValueThis value indicates the number of days that the Powermonitor II

Página 64

General Operation 4-311403-IN001A-US-PDisplay Module # 1, #2, #3 Firmware Revision NumberThis parameter returns the firmware revision number of the re

Página 65 - General Operation 4-29

4-32 General Operation1403-IN001A-US-P

Página 66 - 4-30 General Operation

1403-IN001A-US-PAppendix ACatalog Number ExplanationMaster Module/Limited Metering Master ModuleDisplay Module1403 - MM 01 ABulletin Number Type of De

Página 67 - General Operation 4-31

1403-IN001A-US-PPreface Using This Instruction SheetWhat This Instruction Sheet ContainsReview the table below to familiarize yourself with the topics

Página 68 - 4-32 General Operation

A-2 Catalog Number Explanation1403-IN001A-US-PCommunications Cards/Peripherals/SoftwareFiber Optic Accessories1403 - NSCBulletin NumberType of Dev

Página 69 - 1403 - DM A

1403-IN001A-US-PAppendix BMechanical DimensionsFigure B.1 Master Module Dimensions

Página 70 - 1403 - NSC

B-2 Mechanical Dimensions1403-IN001A-US-PFigure B.2 Display Module Dimensions

Página 71 - Mechanical Dimensions

Mechanical Dimensions B-31403-IN001A-US-PFigure B.3 Display Module MountingFigure B.4 Display Module Cutout Dimensions

Página 72 - B-2 Mechanical Dimensions

B-4 Mechanical Dimensions1403-IN001A-US-PFigure B.5 Installation of the Display Module into the Protective EnclosureGasketProtective Enclosure Front P

Página 73 - Mechanical Dimensions B-3

±1Variable Content TTL:Chap Is Linked To HD:Running

Página 74 - Protective Enclosure

±3Variable Content TTL:Chap Is Linked To HD:Running

Página 75 - TTL:Chap

1403-IN001A-US-PAppendix CTechnical SpecificationsProduct ApprovalsUL 508 listed, File E96956, for Industrial Control Equipment and CSA C22.2 Certifie

Página 76 - Is Linked To HD:Running

C-2 Technical Specifications1403-IN001A-US-PMeasurement Accuracy, Resolution, and RangeSee table below for the rating of each parameter.Parameter Accu

Página 77 - Technical Specifications

Technical Specifications C-31403-IN001A-US-PGeneral Input, Output, and Environmental RatingsInput and Output Ratings Control Relay Relay LifeGeneral S

Página 78 - C-2 Technical Specifications

P-2 Using This Instruction Sheet1403-IN001A-US-PTerms and ConventionsIn this manual, the following terms and conventions are used:Battery: In this man

Página 79 - Technical Specifications C-3

C-4 Technical Specifications1403-IN001A-US-P

Página 80 - C-4 Technical Specifications

1403-IN001A-US-PAppendix DGlossaryAampereA unit of electrical current or rate of flow of electrons. One volt across one ohm of resistance causes a cur

Página 81 - Glossary

D-2 Glossary1403-IN001A-US-Pdemand intervalDemand charges are based on peak demand over a utility specified time interval, not on the instantaneous de

Página 82 - D-2 Glossary

Glossary D-31403-IN001A-US-POohmThe unit of electrical resistance. One ohm is the value of resistance through which a potential difference of one volt

Página 83 - Glossary D-3

D-4 Glossary1403-IN001A-US-PresistanceThe property of a substance which impedes current flow and results in the dissipation of power in the form of he

Página 84 - D-4 Glossary

1403-IN001A-US-PIndexBbattery replacement 3-1disposal 3-3installation 3-1removal 3-2Ccalibration 3-3catalog number explanation A-1cleaning instruction

Página 85

1403-IN001A-US-PI-2general purpose status bits 4-31master module auxiliary frequency 4-31master module data acquisition status 4-29master module devic

Página 86

1403-IN001A-US-PI-3

Página 87

Publication 1403-IN001A-US-P - August 1999 PN 40055-161-02(B)Supersedes Publication 1403-5.0 November 1997 and Publication 1403-5.0-DU3 August 1998 ©

Página 88 - Back Cover

1403-IN001A-US-PChapter 1Product DescriptionChapter ObjectivesAfter completing this chapter, you should be able to identify the product features and s