Rockwell-automation 1402-LSM Line Synchronization Module Installation Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Equipamento Rockwell-automation 1402-LSM Line Synchronization Module Installation . Rockwell Automation 1402-LSM Line Synchronization Module Installation Instructions User Manual [en] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Installation

ALLEN-BRADLEYInstallationand OperationManualLine SynchronizationModule(Bulletin 1402 LSM)Allen-Bradley

Página 2 - • recognize the consequences

Chapter 1Product Description1–4

Página 3 - Table of Contents

A–B2Chapter2–1InstallationThe Bulletin 1402 Line Synchronization Module (LSM) should be installedin a Bulletin 1771 I/O chassis that is located in a d

Página 4

Chapter 2Installation2–2The LSM requires the use of a Cat. No. 1771-WC (10 position, goldcontacts) Swing Arm.There are two sets of terminals associate

Página 5 - Using This Manual

Chapter 2Installation2–3For proper monitoring and synchronization, correct selection of currenttransformers (CT’s) and potential transformers (PT’s) i

Página 6 - Terms and Conventions

Chapter 2Installation2–4Other factors may affect CT accuracy. The length of the CT cabling shouldbe minimized because long cabling could contribute to

Página 7

Chapter 2Installation2–5Connection for Three Phase Delta, 3 Wire Systems with 3 PT’s & 3 CT’SWhen configured for ungrounded (floating) Delta opera

Página 8 - • Synchronization Status

Chapter 2Installation2–6Current Transformer ConnectionsThe LSM is equipped with four CT inputs, designated I1 – I4. Inputs I1 – I3are used to measure

Página 9 - Module Configuration

Chapter 2Installation2–7Figure 2.1 – Wiring Diagram for 4–Wire Wye ConnectionSynchronizing Bus VoltageL1 L2 L3 NCT Terminal Block12345678A0234571BRefe

Página 10 - Product Description

Chapter 2Installation2–8Figure 2.2 – Wiring Diagram for 3–Wire Wye ConnectionSynchronizing Bus VoltageL1 L2 L3CT Terminal Block12345678A023451BReferen

Página 11

Chapter 2Installation2–9Figure 2.3 – Wiring Diagram for 3 Transformer Delta ConnectionSynchronizing Bus VoltageL1 L2 L3CT Terminal Block12345678A02345

Página 12 - Swing Arm

Solid state equipment has operational characteristics differing from those ofelectromechanical equipment. “Safety Guidelines for the Application,Insta

Página 13 - Selection

Chapter 2Installation2–10Figure 2.4 – Wiring Diagram for 2 Transformer Open–Delta ConnectionSynchronizing Bus VoltageL1 L2 L3CT Terminal Block12345678

Página 14 - Chapter 2

Chapter 2Installation2–11Figure 2.5 – Wiring Diagram for 2 Transformer Open–Delta Connection With 2 CT’sSynchronizing Bus VoltageL1 L2 L3CT Terminal B

Página 15

Chapter 2Installation2–12

Página 16 - Calibration

A–B3Chapter3–1General OperationThis chapter:• introduces the user to the controls and operation• describes each function• defines operating parameter

Página 17 - Figure 2.1

Chapter 3General Operation3–2Voltage ModeThis entry is used to indicate if the system being monitored is wired in aWYE, a Delta, or an open Delta. A v

Página 18 - Figure 2.2

Chapter 3General Operation3–3Phase Match Error Upper and Lower Acceptance LimitsThese entries are used to specify the upper and lower acceptance limit

Página 19 - Figure 2.3

Chapter 3General Operation3–4Demand PeriodThis entry is used to specify the desired period for demand measurement.The value is specified in minutes an

Página 20 - Figure 2.4

Chapter 3General Operation3–5Synchronization ContinuedThe “Permissive Synchronization” discrete output from the PLC–5 preventsthe LSM from issuing any

Página 21 - Figure 2.5

Chapter 3General Operation3–6Power MonitoringIn addition to the synchronization function, the LSM provides an extensivearray of monitoring information

Página 22

Chapter 3General Operation3–7Load SharingThe load sharing function allows multiple synchronizing buses to split theload requirements on a power system

Página 23 - General Operation

Table of ContentsiProduct Description 1–1. . . . . . . . . . . . . . . . . . . . . . . . . . Chapter Objectives 1–1. . . . . . . . . . . . . . . . . .

Página 24 - Chapter 3

Chapter 3General Operation3–8ControlThe user can direct the LSM to perform several different functions bysending the appropriate block transfer data t

Página 25

Chapter 3General Operation3–9Self–test ContinuedThe red Fault LED flashes while the complete self–test is being performed.The Fault LED will remain on

Página 26

Chapter 3General Operation3–10Discrete Outputs (From the PLC Processor)The following discrete output control signals will be provided from thePLC–5 pr

Página 27

Chapter 3General Operation3–11Configuration Software Support6200 SoftwareSetup assistance for the LSM module is provided through the 6200 version4.4 o

Página 28

Chapter 3General Operation3–12

Página 29

A–B4Chapter4–1Application InformationModes of OperationThe Line Synchronization Module (LSM) has several modes of operation.Upon successful configurat

Página 30

Chapter 4Application Information4–2Synchronization and Monitor with Load ShareIn this mode of operation, data is returned for Synchronizing Bus voltag

Página 31 - Discrete I/O Interface

Chapter 4Application Information4–3Block Transfer Communications ContinuedFor example, the words 10 modulus 103 and 0 modulus 100 would beprocessed in

Página 32 - PLC Interface Continued

Chapter 4Application Information4–4Acquiring Data From the LSMThe data from the LSM is returned in four tables. These tables are againdifferentiated b

Página 33

Chapter 4Application Information4–5Discrete Outputs From The PLC–5 Continued present, the synchronization fails and the “Synchronization Failure” disc

Página 34

Table of ContentsiiPLC Interface 3–9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Discrete I/O Interface 3–9. . . . . . . . . .

Página 35 - Application Information

Chapter 4Application Information4–6Discrete Inputs to the PLC–5The discrete inputs to the PLC–5 are as follows:Table 4.3Octal BitNumberDecimal BitNumb

Página 36 - Block Transfer Communications

Chapter 4Application Information4–7Discrete Inputs to the PLC–5 ContinuedThe Lower Speed – Frequency Adjust synchronization error discrete input tothe

Página 37 - • modulus 10

Chapter 4Application Information4–8Discrete Inputs to the PLC–5 ContinuedThe Close Breaker discrete input to the PLC–5 indicates that allsynchronizati

Página 38 - Chapter 4

Chapter 4Application Information4–9Data Files UsedTable 4.4Data File Data Descriptionb3/0 Internal Triggerb3/1 Config Mode Enableb3/2 Data Resetb3/3 R

Página 39

Chapter 4Application Information4–10Data Files Used ContinuedThe following description applies to both files N21 and N22.The data at word 0 of N21 and

Página 40

Chapter 4Application Information4–11Data Files Used ContinuedTable 4.5File DescriptionN30 Factory Configuration Parameters BTR DestinationN31 User Con

Página 41

Chapter 4Application Information4–12

Página 42

AAppendixA–1Catalog Number ExplanationLINE SYNCHRONIZATION MODULE1402 - LS 5 15 5A Full ScaleMeasuredCurrentType ofDeviceMeasuredPhaseVoltage1402Power

Página 43 - Continued

Appendix ACatalog Number ExplanationA–2

Página 44

A–BAppendixBB–1Block Transfer and Discrete I/O DefinitionTable B.1LSM Data Table ListTable NameNumber of ParametersID/Numberof WordsType of TableFacto

Página 45 - = frequency in floating point

A–BPreface iUsing This ManualReview the table below to familiarize yourself with the topics contained inthis manual.For information about: Refer to ch

Página 46

Appendix BBlock Transfer and DiscreteI/O DefinitionB–2Table B.2Factory Configuration ParametersParameterNumberWordNum-berDescription Range Modulus 1 –

Página 47 - Catalog Number Explanation

I/O DefinitionAppendix BBlock Transfer and DiscreteB–3Table B.2Factory Configuration Parameters (Continued)ParameterNumberWord Number Description Rang

Página 48 - Appendix

Appendix BBlock Transfer and DiscreteI/O DefinitionB–4Table B.3User Configuration ParametersParameterNumberWordNumberDescription Range Modulus11 Deman

Página 49

I/O DefinitionAppendix BBlock Transfer and DiscreteB–5Table B.4Acknowledge Factory Configuration ParametersParameterNumberWordNumberDescription Range

Página 50

Appendix BBlock Transfer and DiscreteI/O DefinitionB–6Table B.5Acknowledge User Configuration ParametersParameterNumberWordNumberDescription Range Mod

Página 51

I/O DefinitionAppendix BBlock Transfer and DiscreteB–7Table B.6Synchronizing Bus Error ParametersParameterNumberWordNumberDescription Range Modulus1 1

Página 52

Appendix BBlock Transfer and DiscreteI/O DefinitionB–8Table B.7Synchronizing Bus Voltage/Current ParametersParameterNumberWordNumberDescription Range

Página 53

I/O DefinitionAppendix BBlock Transfer and DiscreteB–9Table B.7Synchronizing Bus Voltage/Current Parameters (Continued)ParameterNumberWordNumberDescri

Página 54

Appendix BBlock Transfer and DiscreteI/O DefinitionB–10Table B.8Synchronizing Bus Power ParametersParameterNumberWordNumberDescription Range Modulus1

Página 55

I/O DefinitionAppendix BBlock Transfer and DiscreteB–11Table B.8Synchronizing Bus Power Parameters (Continued)ParameterNumberWordNumberDescription Ran

Página 56

PrefaceUsing This Manual iiIn this manual, the following terms and conventions are used:Abbreviation TermAWG American Wire GageBTR Block Transfer Read

Página 57

Appendix BBlock Transfer and DiscreteI/O DefinitionB–12Table B.9Reference Bus Voltage ParametersParameterNumberWordNumberDescription Range Modulus1 1V

Página 58

I/O DefinitionAppendix BBlock Transfer and DiscreteB–13Table B.10Control Request ParametersParameterNumberWordNumberDescriptionRangeIndividualBitsModu

Página 59

Appendix BBlock Transfer and DiscreteI/O DefinitionB–14Table B.11Diagnostic ParametersParameterNumberWordNumberDescription Range Modulus1 1 0 – 999

Página 60

I/O DefinitionAppendix BBlock Transfer and DiscreteB–15Table B.11Diagnostic Parameters (Continued)ParameterNumberWordNumberDescription Range Modulus A

Página 61

Appendix BBlock Transfer and DiscreteI/O DefinitionB–16Table B.11Diagnostic Parameters (Continued)ParameterNumberWordNumberDescription Range Modulus18

Página 62

I/O DefinitionAppendix BBlock Transfer and DiscreteB–17Table B.13Discrete Input/Output DataDecimalBit NumberOctal BitNumberDiscrete Output(from Proces

Página 63

Appendix BBlock Transfer and DiscreteI/O DefinitionB–18

Página 64

A–BCAppendixC–1Sample Ladder ListingThis is a sample ladder. It shows a way to configure the block transfers forthe 1402–LSM and the Power I/O Config

Página 65

Appendix CSample Ladder ListingC–2Rung 2:2 The trigger must be present and the run sequence must be complete for the config mode to be enabled.

Página 66 - I/O Definition

Appendix CSample Ladder ListingC–3Rung 2:5 Resets configuration mode sequencer when in the run mode.| Config

Página 67 - Sample Ladder Listing

A–B1Chapter1–1Product DescriptionAfter reading this chapter, you should be able to identify the product featuresand system applications.The Bulletin 1

Página 68 - Appendix C

Appendix CSample Ladder ListingC–4Rung 2:8 Sequence through pre–selected block transfers when the active block transfer has completed or has enc

Página 69

Appendix CSample Ladder ListingC–5Rung 2:11 Perform BTR User Configuration Parameters.| Us

Página 70

Appendix CSample Ladder ListingC–6Rung 2:14 Perform BTR Synchronizing Bus Error Parameters.|

Página 71

Appendix CSample Ladder ListingC–7Rung 2:17 Perform BTR Reference Bus Voltage Parameters.|

Página 72

Appendix CSample Ladder ListingC–8Rung 2:20 Perform BTW for User Configuration Parameters.|

Página 73

Appendix CSample Ladder ListingC–9Rung 2:23 Configuration data is valid and the sequence is complete.|

Página 74

Appendix CSample Ladder ListingC–10

Página 75

DAppendixD–1Line Synchronization ModuleMechanical DimensionsFigure 1Dimensions for Line Synchronization Module1.57( .06 )6.73( .27 )31.72( 1.25 )62.2

Página 76

Appendix DMechanical DimensionsD–2

Página 77 - Mechanical Dimensions

A–BAppendixEE–1Bulletin 1402 Technical SpecificationsINPUTS:Current 0 to 5A RMS Cont., 200A RMS 1 SecondFrequency 40 to 100 Hz (steady-state)Dielectri

Página 78 - Appendix D

Chapter 1Product Description1–2In order to synchronize two three phase systems without high instantaneousenergy transfer, the voltage, frequency, and

Página 79

Appendix ETechnical SpecificationsE–2CSA certifies products for general use as well as for use in hazardouslocations. Actual CSA certification is ind

Página 80 - CODE T3C

Appendix EPower Monitoring E–3La CSA certifie les produits d’utilisation générale aussi bien que ceux quis’utilisent dans des emplacements. La certifi

Página 81 - Approbation d’utilisation

Appendix ETechnical SpecificationsE–4If this product has the CE mark it is approved for installation within theEuropean Union and EEA regions. It has

Página 86

Allen-Bradley, a Rockwell Automation Business, has been helping its customers improveproductivity and quality for more than 90 years. We design, manuf

Página 87 - Worldwide representation

Chapter 1Product Description1–3In addition to the synchronization function, the LSM provides an extensivearray of monitoring information for systems w

Comentários a estes Manuais